IEC 60512-9-3:2011
Current
Connectors for electronic equipment - Tests and measurements - Part 9-3: Endurance tests - Test 9c: Mechanical operation (engaging and separating) with electrical load
Hardcopy , PDF
English - French
06-22-2011
FOREWORD
1 Scope and object
2 Normative references
3 Preparation
4 Test method
5 Details to be specified
Annex A (informative) - Typical circuit diagram
IEC 60512-9-3:2011 defines a standard test method to assess the mechanical and electrical operational endurance, i.e. engaging and separating cycles, of a connector in an operating mode which includes a specified electrical load. This second edition cancels and replaces Test 9c of IEC 60512-5, issued in 1992, and constitutes a technical revision. The main technical changes with regard to the previous edition are as follows:
- An additional requirement to 4.1 stating that if more than one electrical circuit is wired for testing, the wiring shall be carried out in a parallel electrical circuit.
- Subclauses 4.3 through 4.7 were removed and replaced by 4.2 through 4.4.
This publication is to be read in conjunction with ;a href=;http:;;webstore.iec.ch;webstore;webstore.nsf;ArtNum_PK;26692;;IEC 60512-1:2001;;a; and ;a href=;http:;;webstore.iec.ch;webstore;webstore.nsf;ArtNum_PK;35881;;IEC 60512-1-100:2006;;a;.
| Committee |
TC 48/SC 48B
|
| DevelopmentNote |
To be read in conjunction with IEC 60512-1 and IEC 60512-1-100. (02/2006) Stability Date: 2017. (10/2012)
|
| DocumentType |
Standard
|
| Pages |
17
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NBN EN 60512-9-3 : 2011 | Identical |
| NEN EN IEC 60512-9-3 : 2011 | Identical |
| PN EN 60512-9-3 : 2011 | Identical |
| VDE 0687-512-9-3:2012-04 | Identical |
| DIN EN 60512-9-3:2012-04 | Identical |
| BS EN 60512-9-3:2011 | Identical |
| CEI EN 60512-9-3 : 2012 | Identical |
| EN 60512-9-3:2011 | Identical |
| I.S. EN 60512-9-3:2011 | Equivalent |
| UNE-EN 60512-9-3:2011 | Identical |
| I.S. EN 60512-9-3:2011 | Identical |
| UNE-EN 60512-9-3:2006 | Identical |
| BS EN 60793-1-48:2007 | Identical |
| NF EN 60512-9-3 : 2012 | Identical |