IEC 60601-1-3:2008+AMD1:2013 CSV
Superseded
View Superseded by
Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
Hardcopy , PDF
English - French
04-19-2013
01-29-2021
FOREWORD
INTRODUCTION
INTRODUCTION TO AMENDMENT 1
1 Scope, object and related standards
2 Normative references
3 Terms and definitions
4 General requirements
5 ME EQUIPMENT identification, marking and documents
6 RADIATION management
7 RADIATION QUALITY
8 Limitation of the extent of the X-RAY BEAM and
relationship between X-RAY FIELD and IMAGE
RECEPTION AREA
9 FOCAL SPOT TO SKIN DISTANCE
10 ATTENUATION of the X-RAY BEAM between the PATIENT
and the X-RAY IMAGE RECEPTOR
11 Protection against RESIDUAL RADIATION
12 Protection against LEAKAGE RADIATION
13 Protection against STRAY RADIATION
Annex A (informative) - General guidance and rationale
Annex B (normative) - Values of the series R'10 and
R'20, ISO 497
Annex C (informative) - Mapping between this Edition 2 of
IEC 60601-1-3 and Edition 1
Bibliography
IEC 60601-1-3:2008+A1:2013 applies to X-ray equipment and to subassemblies of such equipment, where radiological images of a human patient are used for diagnosis, planning or guidance of medical procedures. The object of this collateral standard is to establish general requirements for protection against X-radiation in X-ray equipment, in order that the irradiation of the human patient, the operator, staff and members of the public can be kept as low as reasonably achievable, without jeopardizing the benefit of the radiological procedure. Particular standards may specify their appropriate values and/or measures for general requirements specified in this collateral standard. The implementation of the general requirements or the reference to the particular standard instead, shall be justified in the risk management process. This collateral standard considers radiation protection aspects related to X-radiation only. Requirements for the control of the electrical energy used to generate X-radiation, which is also an important aspect of radiation protection, are included in IEC 60601-1 and in particular standards for the safety and essential performance of the equipment concerned. This document cancels and replaces the first edition of IEC 60601-1-3, published in 1994 (which replaced IEC 60407 issued in 1973). It constitutes a technical revision. This edition has been restructured and aligned to IEC 60601-1(2005) and focussed on general requirements for RADIATION PROTECTION that apply to all diagnostic X-RAY EQUIPMENT. Requirements particular to specific equipment have been removed and will be covered in particular standards. For a description of the changes, see the mapping in Annex C. This consolidated version consists of the second edition (2008) and its amendment 1 (2013). Therefore, no need to order amendment in addition to this publication.
| Committee |
TC 62/SC 62B
|
| DevelopmentNote |
Supersedes IEC 60407, IEC 60407A (03/2001) Supersedes IEC 60601-2-32. (11/2012) Stability Date: 2019. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
100
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| GOST R IEC 60601-1-3 : 2013 | Identical |
| NEN EN IEC 60601-1-3 : 2008 AMD 11 2016 | Identical |
| I.S. EN 60601-1-3:2008 | Identical |
| AS/NZS IEC 60601.1.3:2015 | Identical |
| DIN EN 60601-1-3 : 2014 | Identical |
| VDE 0750-1-3 : 2014 | Identical |
| BS EN 60601-1-3 : 2008 | Identical |
| EN 60601-1-3 : 2008 AMD 11 2016 | Identical |
| ABNT NBR IEC 60601-1-3:2016 | Identical |
| UNE-EN 60601-1-3:2008 | Identical |
| NEN 10601-1-3 : 1994 | Identical |
A newer version of this standard is available.
View Current Edition