IEC 60601-2-25:2011
Current
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs
Hardcopy , PDF
English - French
10-19-2011
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT
and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and other
HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and
ME SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - ELECTRODES, their positions,
identifications and colour codes
Annex CC (informative) - LEADS, their identification and
colour codes (other than those specified in
201.12.4.102)
Annex DD (informative) - Polarity of PATIENT LEADS
(other than those specified in 201.12.4.102)
Annex EE (informative) - Additional marking of ELECTRODES
Annex FF (informative) - Definitions and rules for the
measurement of ELECTROCARDIOGRAMS
Annex GG (informative) - Calibration and test data sets
Annex HH (informative) - CTS test atlas
Bibliography
Index of defined terms used in this particular standard
IEC 60601-2-25:2011 applies to the basic safety and essential performance of electrocardiographs intended by themselves or as a part of a medical electrical system, for the production of electrocardiogram reports for diagnostic purposes. The equipment intended for use under extreme or uncontrolled environmental conditions outside the hospital environment or physician's office, such as in ambulances and air transport, shall comply with this particular standard. Additional standards may apply to Medical electrical equipment for those environments of use. Not included within the scope of this particular standard are:
a) the part of Medical electrical equipment that provides vectorcardiographic loops;
b) ambulatory electrocardiographic medical electrical equipment covered by IEC 60601-2-47 where not intended for obtaining electrocardiogram reports for diagnostic purposes;
c) cardiac monitors covered by IEC 60601-2-27 where not intended for obtaining electrocardiographic reports for diagnostic purposes.
This second edition cancels and replaces the first edition of IEC 60601-2-25, published in 1993 and the first edition of IEC 60601-2-51, published in 2003. Updating the particular standards to refer to the third edition of the general standard provided the opportunity to merge the first editions of IEC 60601-2-25 and IEC 60601-2-51 into one standard. Reformatting and technical changes were both made. This second edition of IEC 60601-2-25 constitutes a technical revision of both those standards.
| Committee |
TC 62/SC 62D
|
| DevelopmentNote |
Supersedes IEC 60601-2-51. (10/2011) Stability Date: 2018. (10/2017). This standard was just updated in our system however it was originally released on 10-2011
|
| DocumentType |
Standard
|
| ISBN |
978-2-88912-719-1
|
| Pages |
196
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| VDE 0750-2-25:2016-08 | Identical |
| NEN EN IEC 60601-2-25 : 2015 | Identical |
| I.S. EN 60601-2-25:2015 | Identical |
| AS/NZS IEC 60601.2.25:2016 | Identical |
| PN EN 60601-2-25 : 2016 | Identical |
| DIN EN 60601-2-25:2016-08 | Identical |
| VDE 0750-2-25 : 2001 | Identical |
| IS 13450 : Part 2 : Sec 25 : 2018 | Identical |
| BS EN 60601-2-25:2015 | Identical |
| CEI EN 60601-2-25 : 2016 | Identical |
| EN 60601-2-25:2015 | Identical |
| JIS T 0601-2-25:2014 | Identical |
| ANSI/AAMI/IEC 60601-2-25:2011(R2016) | Identical |
| AAMI EC11 : 1991 | Identical |
| UNE-EN 60601-2-25:2016 | Identical |
| CSA C22.2 No. 601.2.25A : 2002 | Identical |
| AAMI IEC 60601-2-25 : 2011 | Identical |
| NEN 10601-2-25 : 1996 | Identical |
| BS 5724-2.125(1993) : 1993 AMD 8112 | Identical |