IEC 60601-2-47:2012
Current
Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems
Hardcopy , PDF
English - French
02-16-2012
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME
EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT
and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and other
HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
and ME SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Bibliography
Index of defined terms used in this particular standard
IEC 60601-2-47:2012 concerns the basic safety and essential performance of AMBULATORY ELECTROCARDIOGRAPHIC SYSTEMS. It amends and supplements the general standard IEC 60601-1 (third edition 2005). The requirements of this particular standard take priority over those of the general standard. Within the scope of this standard are systems of the following types:
a) systems that provide continuous recording and continuous analysis of the ECG allowing full re-analysis giving essentially similar results.
b) systems that provide continuous analysis and only partial or limited recording not allowing a full re-analysis of the ECG.
The safety aspects of this standard apply to all types of systems falling in one of the above- mentioned categories. If the AMBULATORY ELECTROCARDIOGRAPHIC SYSTEM offers automatic ECG analysis, minimal performance requirements for measurement and analysis functions apply. MEDICAL ELECTRICAL EQUIPMENT covered by IEC 60601-2-25 and IEC 60601-2-27 are excluded from the scope of this standard. This standard does not apply to systems that do not continuously record and analyse the ECG (for example, 'intermittent event recorders'). This second edition cancels and replaces the first edition published in 2001. It constitutes a technical revision. This edition was revised to align structurally with the 2005 edition of IEC 60601-1.
| Committee |
TC 62/SC 62D
|
| DevelopmentNote |
Stability Date: 2018. (10/2017)
|
| DocumentType |
Standard
|
| Pages |
135
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NBN EN 60601 2-47 : 2015 | Identical |
| NEN EN IEC 60601-2-47 : 2015 | Identical |
| PN EN 60601-2-47 : 2015 | Identical |
| VDE 0750-2-47:2016-02 | Identical |
| IS 13450 : Part 2 : Sec 47 : 2018 | Identical |
| BS EN 60601-2-47:2015 | Identical |
| CEI EN 60601-2-47 : 2016 | Identical |
| EN 60601-2-47:2015 | Identical |
| NF EN 60601 2-47 : 2015 | Identical |
| CEI EN 60601-2-47:2018 | Identical |
| ANSI/AAMI/IEC 60601-2-47:2012(R2016) | Identical |
| UNE-EN 60601-2-47:2002 | Identical |
| DIN EN 60601-2-47:2016-02 | Identical |
| UNE-EN 60601-2-47:2015 | Identical |
| BS EN 60745-2-15:2006 | Identical |
| AAMI IEC 60601-2-47 : 2012 | Identical |
| AAMI EC38 : 2007 | Identical |