IEC 61347-2-9:2012

Current

Current

Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

10-30-2012

US$371.00
Excluding Tax where applicable
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Electromagnetic controlgear heating
15 High-voltage impulse testing
16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
22 No-load output voltage
Annex A (normative) - Test to establish whether a
        conductive part is a live part which may
        cause an electric shock
Annex B (normative) - Particular requirements for
        thermally protected lamp electromagnetic
        controlgear
Annex C (normative) - Particular requirements
        for electronic lamp controlgear with
        means of protection against overheating
Annex D (normative) - Requirements for carrying
        out the heating tests of thermally protected
        lamp electromagnetic controlgear
Annex E (normative) - Use of constant S other
        than 4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation
        of the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Method for selection of varistors
Annex J (informative) - Explanation of electromagnetic
        controlgear temperatures
Annex K (normative) - Additional requirements for
        built-in electromagnetic controlgear with
        double or reinforced insulation
Bibliography

IEC 61347-2-9:2012 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This second edition cancels and replaces the first edition published in 2000, Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a new Clause 14;
b) the word "ballast" is changed to "electromagnetic controlgear".

This publication is to be read in conjunction with IEC 61347-1:2007.

Committee
TC 34/SC 34C
DevelopmentNote
Supersedes IEC 60922 (01/2001) To be used in conjunction with IEC 61347-1. (11/2003) Stability date: 2020. (09/2017)