IEC 61643-1:2005
Superseded
View Superseded by
Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests
Hardcopy , PDF
English - French
03-30-2005
03-09-2011
FOREWORD
INTRODUCTION
1 General
1.1 Scope
1.2 Normative references
2 Service conditions
2.1 Normal
2.2 Abnormal
3 Definitions
4 Classifications
4.1 Number of ports
4.2 SPD design topology
4.3 SPD class I, II and III tests
4.4 Location
4.5 Accessibility
4.6 Mounting method
4.7 SPD disconnector
4.8 Overcurrent protection
4.9 Degree of protection provided by enclosures according
to IP codes of IEC 60529
4.10 Temperature range
4.11 System
4.12 Multipole SPD
5 Standard ratings
5.1 Preferred values of impulse current for class I
tests I[imp]
5.2 Preferred values of nominal discharge current for
class II tests I[n]
5.3 Preferred values of open-circuit voltage for class
III tests U[oc]
5.4 Preferred values of voltage protection level U[p]
5.5 Preferred values of r.m.s. or d.c. maximum continuous
operating voltage U[c]
6 Requirements
6.1 General requirements
6.2 Electrical requirements
6.3 Mechanical requirements
6.4 Environmental requirements
6.5 Safety requirements
6.6 Additional test requirements for two-port SPDs and
one-port SPDs with separate input/output terminals
7 Type tests
7.1 General testing procedures
7.2 Identification and marking
7.3 Terminals and connections
7.4 Testing for protection against direct contact
7.5 Determination of the measured limiting voltage
7.6 Operating duty test
7.7 SPD disconnectors and safety performance of
overstressed SPDs
7.8 Test for two-port SPDs and one-port SPDs with separate
input/output terminals
7.9 Additional tests
8 Routine and acceptance tests
8.1 Routine tests
8.2 Acceptance tests
Annex A (informative) Considerations for SPDs when class I
tests are to be applied
Annex B (normative) TOV values
Bibliography
This part of IEC 61643 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are packaged to be connected to 50/60 Hz a.c. and d.c. power circuits, and equipment rated up to 1 000 V r.m.s. or 1 500 V d.c. Performance characteristics, standard methods for testing, and ratings are established for these devices that contain at least one nonlinear component that is intended to limit surge voltages and divert surge currents.
| Committee |
TC 37/SC 37A
|
| DocumentType |
Standard
|
| Pages |
159
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| VDE 0675-6-11 : 2013 | Identical |
| UNE-EN 61643-11:2013 | Identical |
| I.S. EN 61643-11:2012 | Identical |
A newer version of this standard is available.
View Current Edition