IEC 62271-105:2012
Superseded
View Superseded by
High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
Hardcopy , PDF
English - French
09-27-2012
12-31-2021
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide for the selection of switch-fuse combinations
9 Information to be given with enquiries, tenders
and orders
10 Transport, storage, installation, operation and
maintenance
11 Safety
12 Influence of the product on the environment
Annex A (informative) - Example of the coordination
of fuses, switch and transformer
Annex B (normative) - Procedure for determining
transfer current
Annex C (normative) - Tolerances on test quantities
for type tests
Bibliography
IEC 62271-105:2012 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of
- breaking, at the rated recovery voltage, any current up to and including the rated short-circuit breaking current;
- making, at the rated voltage, circuits to which the rated short-circuit breaking current applies.
It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporating single capacitor bank switches. This second edition cancels and replaces the first edition of IEC 62271-105, published in 2002, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- implementation of figures at the place where they are cited first;
- renumbering of tables;
- addition of some of the proposals from IEC paper 17A/852/INF;
- addition of missing subclauses of IEC 62271-1;
- implementation of 6.105 "Extension of validity of type tests" and consequently removing of the relevant parts in the different existing clauses;
- change of 7th paragraph of 6.101.4 as there is now a definition of NSDD given in 3.7.4 of IEC 62271-1:2007. Harmonization with IEC 62271-107;
- some referenced clauses in other standards like IEC 60282-1 were changed and therefore changed the editions under 1.2 to the ones referred to;
- addition of a new Annex C defining tolerances.
This publication is to be read in conjunction with IEC 62271-1:2007.
| Committee |
TC 17/SC 17A
|
| DevelopmentNote |
Supersedes IEC 60420. (08/2002) To be read in conjunction with IEC 62271-1. (09/2012) Stability Date: 2020. (11/2017)
|
| DocumentType |
Standard
|
| Pages |
104
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| DS EN 62271-105 : 2013 | Identical |
| NF EN 62271-105 : 2013 | Identical |
| NEN EN IEC 62271-105 : 2013 | Identical |
| PN EN 62271-105 : 2013 | Identical |
| AS IEC 62271.105:2015 | Identical |
| DIN EN 62271-105 : 2013-08 | Identical |
| VDE 0671-105 : 2013-08 | Identical |
| BS EN 62271-105:2012 | Identical |
| CEI EN 62271-105 : 2014 | Identical |
| EN 62271-105:2012 | Identical |
| I.S. EN 62271-105:2012 | Equivalent |
| UNE-EN 62271-105:2013 | Identical |