• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

IEC 80601-2-30:2018

Current

Current

Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

03-22-2018

US$478.00
Excluding Tax where applicable
Summarise this standard

FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and
        documents
201.8 Protection against electrical HAZARDS from ME
        EQUIPMENT
201.9 Protection against mechanical HAZARDS of ME
        EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
        radiation HAZARDS
201.11 Protection against excessive temperatures
        and other HAZARDS
201.12 Accuracy of controls and instruments and
        protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
        for ME EQUIPMENT
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS
        (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
        and ME SYSTEMS
201.101 Requirements for CUFFS
201.102 Connection tubing and CUFF connectors
201.103 Unauthorized access
201.104 Maximum inflating time
201.105 Automatic cycling modes
201.106 Clinical accuracy
202 Electromagnetic disturbances - Requirements and
        tests
206 Usability
210 Requirements for the development of physiologic
        closed-loop controllers
211 Requirements for medical electrical equipment
        and medical electrical systems used in the
        home healthcare environment
212 Requirements for medical electrical equipment
        and medical electrical systems intended for
        use in the emergency medical services environment
Annexes
Annex C (informative) - Guide to marking and labelling
        requirements for ME EQUIPMENT and
        ME SYSTEMS
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - Environmental aspects
Annex CC (informative) - Reference to the ESSENTIAL PRINCIPLES
Bibliography
Index of defined terms

IEC 80601-2-30:2018 applies to the basic safety and essential performance of automated sphygmomanometers, hereafter referred to as ME equipment, which by means of an inflatable cuff, are used for non continuous indirect estimation of the blood pressure without arterial puncture. This document specifies requirements for the basic safety and essential performance for this ME equipment and its accessories, including the requirements for the accuracy of a determination. This document covers automatic electrically-powered ME equipment used for the intermittent, indirect estimation of the blood pressure without arterial puncture, including blood pressure monitors for the home healthcare environment. Requirements for indirect estimation of the blood pressure without arterial puncture ME equipment with an electrically-powered pressure transducer and/or displays used in conjunction with a stethoscope or other manual methods for determining blood pressure (non-automated sphygmomanometers) are specified in document ISO 81060-1. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 201.11 and 201.105.3.3, as well as 7.2.13 and 8.4.1 of IEC 60601-1:2005. This second edition cancels and replaces the first edition published in 2009 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 60601-1:2005/AMD1:2012 and IEC 60601-1-8:2006/AMD1:2012 , and with IEC 60601-1-2:2014 and IEC 60601-1-11:2015;
b) referencing IEC 60601-1-10:2007 and IEC 60601-1-12;
c) changing an operator-accessible cuff-sphygmomanometer connector from not compatible with the ISO 594 series to compatible with the ISO 80369 series;
d) added additional requirements for public self-use sphygmomanometers;
e) added a list of primary operating functions.

Committee
TC 62/SC 62D
DevelopmentNote
Supersedes IEC 60601-2-30. (01/2009) Stability Date: 2022. (03/2018)
DocumentType
Standard
Pages
117
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

US$478.00
Excluding Tax where applicable