IEC TR 61400-24:2002

Superseded

Superseded

View Superseded by

Wind turbine generator systems - Part 24: Lightning protection

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

07-11-2002

Superseded date

06-16-2010

US$444.00
Excluding Tax where applicable
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Definitions
3 Lightning and wind turbines
   3.1 The properties of lightning
   3.2 Lightning discharge formation and electrical
        parameters
   3.3 Cloud-to-ground flashes
   3.4 Upward initiated flashes
   3.5 Lightning protection of wind turbines - the generic
        problem
   3.6 Existing IEC standards and technical reports dealing
        with lightning protection
4 Damage statistics
   4.1 Data on wind turbine lightning damage
   4.2 Damage statistics
   4.3 Database merits and weaknesses
   4.4 Conclusions and recommendations
5 Evaluation of the risk of lightning damage to a wind turbine
   5.1 Introduction
   5.2 Assessing the lightning flash frequency to a wind
        turbine
   5.3 Use of IEC 61024-1-1
   5.4 Use of IEC 61662
   5.5 Analysis of blade lightning protection system costs
   5.6 Analysis of lightning protection costs for wind turbine
        control systems
6 Lightning protection of wind turbine blades
   6.1 Blade structure
   6.2 Blade damage mechanism
   6.3 Lightning protection for wind turbine blades
   6.4 Interception efficiency
   6.5 Sizing of materials
   6.6 Blade to hub connection
   6.7 Carbon reinforced plastic (CRP)
   6.8 Wiring inside blades
7 Protection of bearings and gearbox
   7.1 Damage to bearings due to AC and DC currents
   7.2 Damage to bearings due to lightning currents
   7.3 Laboratory investigations
   7.4 Lightning damage to gearbox
   7.5 Lightning protection of bearings and gearbox elements
8 Protection of electrical and control system
   8.1 Introduction
   8.2 Configuration of electrical equipment
   8.3 Lightning protection zones
   8.4 Surge coupling mechanisms
   8.5 Bonding and shielding
   8.6 Surge protection
   8.7 Summary
9 Earthing
   9.1 Lightning protection system earth termination for a
        single wind turbine
   9.2 Lightning protection system earth terminations in a
        wind farm
10 Personnel safety
   10.1 General
11 Conclusions and recommendations for further work
Annex A Typical lightning damage questionnaire
Bibliography
Figures
Tables

Identifies the generic problems involved in lightning protection of wind turbines; describes appropriate methods for evaluating the risk of lightning damage to wind turbines; describes and outlines suitable methods for lightning protection of wind turbine components.

DocumentType
Technical Report
Pages
69
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
NEN NPR IEC/TR 61400-24 : 2002 Identical
PD IEC/TR 61400-24:2002 Identical
UNE-IEC/TR 61400-24:2005 IN Identical
TS C 0041:2005 Identical

⚠

A newer version of this standard is available.

View Current Edition View Current Edition View Current Edition
US$444.00
Excluding Tax where applicable