IEC TS 60695-11-3:2004
Superseded
View Superseded by
Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods
Hardcopy , PDF
English - French
04-19-2004
08-13-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Method A - Production of a standardized 500 W nominal
test flame based on existing hardware
4.1 Requirements
4.2 Apparatus and fuel
4.2.1 Burner
4.2.2 Flowmeter
4.2.3 Manometer
4.2.4 Control valve
4.2.5 Copper block
4.2.6 Thermocouple
4.2.7 Temperature/time indicating/recording and timing
devices
4.2.8 Fuel gas
4.2.9 Laboratory fumehood/chamber
4.3 Production of test flame
4.4 Confirmation of the test flame
4.4.1 Principle
4.4.2 Procedure
4.4.3 Verification
5 Method B (withdrawn)
6 Method C - Production of a standardized 500 W nominal test
flame based on non-adjustable hardware
6.1 Requirements
6.2 Apparatus and fuel
6.2.1 Burner
6.2.2 Flowmeters
6.2.3 Manometer
6.2.4 Control valves
6.2.5 Copper block
6.2.6 Thermocouple
6.2.7 Temperature/time indicating/recording and timing
devices
6.2.8 Fuel gas
6.2.9 Air supply
6.2.10 Laboratory fumehood/chamber
6.3 Production of test flame
6.4 Confirmation of the test flame
6.4.1 Principle
6.4.2 Procedure
6.4.3 Verification
7 Method D (withdrawn)
8 Classification and designation
Annex A (informative) Test method A arrangement
Annex B (withdrawn)
Annex C (normative) Test method C arrangement
Annex D (withdrawn)
Annex E (informative) Recommended arrangements for the use of
the test flames
Annex F (informative) Test arrangements for tests on equipment
Annex G (informative) Test arrangements for tests on material
Annex H (informative) Access to equipment manufacturers and
suppliers
Bibliography
Figure
Provides detailed requirements for the production of a 500 W nominal, pre-mixed type test flame. The approximate overall height is 125 mm.Two test flames are described: Method A may only be produced using methane whereas method C may be produced using either methane or propane.The main changes with respect to the previous edition are described below:- The introduction has been revised, - Test methods B and D have been withdrawn. Test methods A and C have been retained with their original letter designation, - Normative reference ISO 1337 has been withdrawn without a replacement by ISO/TC 26. The callout Cu-ETP UNS 11000 is the replacement for all references to ISO 1337. It is taken from ASTM B187-00 and describes high conductivity electrolytic copper, - A new Annex H has been added which provides access to equipment manufacturers and suppliers,- Alignment with other publications in the IEC 60695-11 series has been made, where appropriate. Has the status of a basic safety publication in accordance withIEC Guide 104.
| Committee |
TC 89
|
| DevelopmentNote |
Supersedes IEC 60695 2-4/2 (03/2001) To be used in conjunction with IEC 60695-1-1 & IEC 60695-11-4 (04/2004) Supersedes IEC 61300-2-36. (03/2008)
|
| DocumentType |
Technical Specification
|
| Pages |
63
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| DD IEC/TS 60695-11-3:2004 | Identical |
| NEN NPR IEC/TS 60695-11-3 : 2004 | Identical |
| AS/NZS 60695.11.3:2004 | Identical |
| TS C 60695-11-3:2006 | Identical |
A newer version of this standard is available.
View Current Edition