IEEE 998-2012
Withdrawn
IEEE Guide for Direct Lightning Stroke Shielding of Substations
English
04-30-2013
03-30-2023
1. Overview
2. Definitions
3. Lightning phenomena
4. The design problem
5. Empirical design methods
6. The electrogeometric model (EGM)
7. Alternative models of lightning interception
Annex A (informative) - Empirical shielding curves
Annex B (informative) - Sample calculations
Annex C (informative) - Calculation of corona radius and
surge impedance under corona
Annex D (informative) - Risk evaluation
Annex E (informative) - IEEE Questionnaire - 2007
Annex F (informative) - The Dainwood method
Annex G (informative) - Direct stroke lightning protection
Annex H (informative) - Methodology review
Annex I (informative) - Comparison of IEEE Std 998 to
other standards
Annex J (informative) - Bibliography
Specifies design procedures to provide direct stroke shielding of outdoor distribution, transmission, and generating plant substations.
| Committee |
Substations
|
| DocumentType |
Standard
|
| Pages |
227
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| Supersedes |
| IEEE 1268-2005 | IEEE Guide for Safety in the Installation of Mobile Substation Equipment |
| IEEE DRAFT C62.22 : D8 2005 | GUIDE FOR THE APPLICATION OF METAL-OXIDE SURGE ARRESTERS FOR ALTERNATING-CURRENT SYSTEMS |
| IEEE C62.82.2-2022 | IEEE Guide for the Application of Insulation Coordination |
| IEEE 1268-2016 REDLINE | IEEE Guide for Safety in the Installation of Mobile Substation Equipment |
| IEEE C62.23-1995 | IEEE Application Guide for Surge Protection of Electric Generating Plants |
| IEEE 1427-2006 | IEEE Guide for Recommended Electrical Clearances and Insulation Levels in Air Insulated Electrical Power Substations |
| 08/30191891 DC : DRAFT OCT 2008 | BS EN 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
| IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
| IEEE 1827-2016 | IEEE Guide for Electrical and Control Design of Hydroelectric Water Conveyance Facilities |
| EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
| IEEE 3001.2:2017 | IEEE Recommended Practice for Evaluating the Electrical Service Requirements of Industrial and Commercial Power Systems |
| IEEE DRAFT 1313.2 : D6 DEC 98 | DRAFT GUIDE FOR THE APPLICATION OF INSULATED COORDINATION |
| IEEE 1862-2014 | IEEE Recommended Practice for Overvoltage and Insulation Coordination of Transmission Systems at 1000 kV AC and Above |
| IEEE 979-2012 REDLINE | IEEE Guide for Substation Fire Protection |
| I.S. EN 61936-1:2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
| IEC TS 61936-2:2015 | Power installations exceeding 1 kV a.c. and 1,5 kV d.c. - Part 2: d.c. |
| PD IEC/TS 61936-2:2015 | Power installations exceeding 1 kV a.c. and 1,5 kV d.c. d.c. |
| BS EN 61936-1 : 2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES |
| UNE-EN 61936-1:2012 | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
| IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
| IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
| IEEE 1243:1997 | GUIDE FOR IMPROVING THE LIGHTNING PERFORMANCE OF TRANSMISSION LINES |
| IEEE 1313-1993 | IEEE Standard for Power Systems - Insulation Coordination |