IEEE C57.135-2011
Withdrawn
IEEE Guide for the Application, Specification, and Testing of Phase-Shifting Transformers
English
08-19-2011
03-24-2022
1. Overview
2. Normative references
3. Definitions
4. Application and theory of PSTs
5. Service conditions
6. Rating data
7. Construction
8. Short-circuit characteristics
9. Control system
10. Testing of PSTs
11. Tolerances
12. Bid document checklist
Annex A (informative) - Bibliography
This guide covers the application, specification, theory of operation, and factory and field testing of singlephase and three-phase oil-immersed, phase-shifting transformers (PSTs).
| Committee |
Transformers
|
| DevelopmentNote |
Supersedes IEEE DRAFT C57.135. (06/2002) Also numbered as IEC 62032. (06/2012)
|
| DocumentType |
Standard
|
| ISBN |
978-0-7381-6691-9
|
| Pages |
50
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| Supersedes |
| IEEE C37.241-2017 | IEEE Guide for Application of Optical Instrument Transformers for Protective Relaying |
| IEEE 1861-2014 | IEEE Guide for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1000 kV AC and Above |
| IEEE C37.91-2008 REDLINE | IEEE Guide for Protecting Power Transformers |
| IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
| IEEE C57.19.100-2012 REDLINE | IEEE Guide for Application of Power Apparatus Bushings |
| IEEE C57.12.10-2010 | TRANSFORMERS - 230 KV AND BELOW 833/958 THROUGH 8333/10 417 KVA, SINGLE-PHASE, AND 750/862 THROUGH 60 000/80 000/100 000 KVA, THREE-PHASE WITHOUT LOAD TAP CHANGING; AND 3750/4687 THROUGH 60 000/80 000/100 000 KVA WITH LOAD TAP CHANGING - SAFETY REQUIREMENT |
| IEEE C57.19.01-2000 | IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings |
| IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
| IEEE C57.93-2007 | IEEE Guide for Installation and Maintenance of Liquid-Immersed Power Transformers |
| IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
| IEEE C57.19.00 : 2004 | GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS |
| IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
| IEEE C57.12.00-2010 REDLINE | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
| IEEE C57.12.80-2010 | IEEE Standard Terminology for Power and Distribution Transformers |
| IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
| IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
| IEC 60076-1:2011 | Power transformers - Part 1: General |
| IEEE C37.90.1-1989 | IEEE Standard Surge Withstand Capability (SWC) Tests for Protective Relays and Relay Systems |
| IEEE C37.90.1-2012 | IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
| IEEE C57.12.70-2011 | IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers |
| ANSI C92.1 : 1982 | POWER SYSTEMS - INSULATION COORDINATION |
| IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
| IEEE C57.131-2012 | IEEE Standard Requirements for Tap Changers |