• Shopping Cart
    There are no items in your cart

IEEE DRAFT C37.09 : D03F JAN 99

Superseded

Superseded

View Superseded by

TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS

Published date

01-12-2013

Superseded date

06-26-1999

Superseded by

IEEE C37.09-1999

Sorry this product is not available in your region.
Summarise this standard

1 Scope
2 Definitions
3 References
4 Design Tests
    4.1 Maximum Voltage Tests
    4.2 Power Frequency Tests
    4.3 Continuous Current Tests
    4.4 Dielectric Withstand Tests
    4.5 Standard Operating Duty Tests
    4.6 Interrupting Time Tests
    4.7 Transient Recovery Voltage Tests
    4.8 Short-Circuit Interrupting Tests
    4.9 Load Current Switching Tests
    4.10 Capacitor Current Switching Tests
    4.11 Line closing Switching Surge Factor
    4.12 Out-of-phase Switching Current Tests
    4.13 Mechanical Endurance Tests
    4.14 Control Voltage
    4.15 Fluid Operating Pressure
    4.16 Design Tests on Porcelain Components
    4.17 Sealed Pressure Systems Leakage Tests
5 Production Tests
    5.1 Types of tests
    5.2 Current and Linear Coupler Tests
    5.3 High-Voltage Circuit Breaker Tests
    5.4 Gas Receiver Tests
    5.5 Pressure Tests
    5.6 Nameplate Check
    5.7 Leakage Tests
    5.8 Vacuum Integrity Tests
    5.9 Resistors, Heaters and Coils Check Tests
    5.10 Control and Secondary Wiring Check Tests
    5.11 Clearance and Mechanical Adjustment Check Tests
    5.12 Mechanical Operation Tests
    5.13 Timing Tests
    5.14 Stored Energy System Tests
    5.15 Electrical Resistance of Current Path Test
    5.16 Power Frequency Withstand Voltage Tests on
          Major Insulation Components
    5.17 Power Frequency Withstand Voltage Tests on Control
          and Secondary Wiring
6 Conformance Test
    6.1 Outdoor Circuit Breakers
    6.2 Indoor Draw-Out Circuit Breakers
7 Standard Methods for Determining the Values of a
    Sinusoidal Current Wave and a Power Frequency Recovery
    Voltage
    7.1 Currents
    7.2 Power Frequency Recovery Voltage
Informative Annexes
A Suggested Short-Circuit Performance Data Form
B Table 1 and Notes from C37.09-1979
C Table 2 and Notes from C37.09-1979

Describes various tests made on AC high voltage indoor drawout and outdoor high-voltage circuit breakers. Gives accepted test procedures and defines tests for verification of assigned ratings under IEEE standards. Does not exclude more effective or equivalent rating demonstrating methods.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy

Sorry this product is not available in your region.