• Shopping Cart
    There are no items in your cart

IEEE DRAFT C57.12.40 : D4 2006

Withdrawn

Withdrawn

View Superseded by

SECONDARY NETWORK TRANSFORMERS, SUBWAY AND VAULT TYPES (LIQUID IMMERSED)

Published date

01-12-2013

Withdrawn date

10-18-2023

Superseded by

IEEE C57.12.40-2011

Sorry this product is not available in your region.

Introduction
1 Overview
   1.1 Scope
   1.2 Purpose
2 References
3 Transformer performance requirements
   3.1 Kilovolt-ampere ratings
   3.2 Voltage rating and tap ratings
   3.3 Angular displacement
   3.4 Basic lightning impulse insulation levels
   3.5 Percent impedance
   3.6 Audible sound levels
4 Tests
5 Primary disconnect and grounding switch
   5.1 General
   5.2 Primary switch electrical performance requirements
   5.3 Primary switch mechanical features
   5.4 Primary switch accessory equipment
   5.5 Primary cable entrance
6 Construction
   6.1 General
   6.2 Corrosion Resistance
   6.3 Tank
   6.4 Accessory equipment for transformer tanks
   6.5 Dimensions
7 Bushings
   7.1 Primary bushings
   7.2 Secondary bushings
   7.3 Terminal markings
8 Neutral termination
   8.1 Primary neutral
   8.2 Secondary neutral
9 Nameplate
10 Connections of transformer for shipment by the manufacturer
Annex A

Describes certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of three-phase, 60 Hz, liquid-immersed, secondary network transformers with a three position grounding switch, subway and vault types, rated 2500 kVA and smaller; primary 34 400 volts and below; secondary 216Y/125 volts and 480Y/277 volts.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
SupersededBy

IEEE C57.12.32-2002 IEEE Standard for Submersible Equipment - Enclosure Integrity
IEEE 386-2016 REDLINE IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
ASME B1.20.1 : 2013(R2018) PIPE THREADS, GENERAL PURPOSE (INCH)
IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers