ISO 14708-6:2010
Withdrawn
Withdrawn
View Superseded by
Implants for surgery — Active implantable medical devices — Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)
Available format(s)
Hardcopy , PDF
Language(s)
English
Published date
02-25-2010
Withdrawn date
04-09-2025
Superseded by
US$96.00
Excluding Tax where applicable
ISO 14708-6:2010 specifies requirements that are applicable to implantable cardioverter defibrillators and the functions of active implantable medical devices intended to treat tachyarrhythmia.
ISO 14708-6:2010 is also applicable to some non-implantable parts and accessories of the devices.
| DevelopmentNote |
DRAFT ISO/DIS 14708-6 is also available for this standard. (03/2018)
|
| DocumentType |
Standard
|
| Pages |
110
|
| ProductNote |
This standard also refers IEC 60878, ANSI/AAMI/ISO PC69
|
| PublisherName |
International Organization for Standardization
|
| Status |
Withdrawn
|
| SupersededBy |
| Standards | Relationship |
| NEN ISO 14708-6 : 2010 | Identical |
| ISO 14117:2012 | Active implantable medical devices — Electromagnetic compatibility — EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices |
| 10/30195946 DC : DRAFT DEC 2010 | BS ISO 27185 - CARDIAC RHYTHM MANAGEMENT DEVICES - SYMBOLS TO BE USED WITH CARDIAC RHYTHM MANAGEMENT DEVICE LABELS, AND INFORMATION TO BE SUPPLIED - GENERAL REQUIREMENTS |
| ASTM F 3020 : 2016 | Performance Standard for Hand-Worn Metal Detectors Used in Safety and Security |
| ASTM F 2401 : 2016 : REDLINE | Standard Practice for Security Checkpoint Metal Detector Screening of Persons with Medical Devices |
| BS ISO 14117:2012 | Active implantable medical devices. Electromagnetic compatibility. EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices |
| ISO 27185:2012 | Cardiac rhythm management devices — Symbols to be used with cardiac rhythm management device labels, and information to be supplied — General requirements |
| ISO 14708-2:2012 | Implants for surgery — Active implantable medical devices — Part 2: Cardiac pacemakers |
| AAMI TIR41 : 2011 | ACTIVE IMPLANTABLE MEDICAL DEVICES - GUIDANCE FOR DESIGNATION OF LEFT VENTRICLE AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEAD CONNECTORS AND PULSE GENERATOR CONNECTOR CAVITIES FOR IMPLANTABLE PACEMAKERS AND IMPLANTABLE CARDIOVERTER DEFIBRILLATORS |
| 10/30208719 DC : 0 | |
| AAMI ISO 14117 : 2012 | ACTIVE IMPLANTABLE MEDICAL DEVICES - ELECTROMAGNETIC COMPATIBILITY - EMC TEST PROTOCOLS FOR IMPLANTABLE CARDIAC PACEMAKERS, IMPLANTABLE CARDIOVERTER DEFIBRILLATORS AND CARDIAC RESYNCHRONIZATION DEVICES |
| AAMI ISO 27185 : 2012 | CARDIAC RHYTHM MANAGEMENT DEVICES - SYMBOLS TO BE USED WITH CARDIAC RHYTHM MANAGEMENT DEVICE LABELS, AND INFORMATION TO BE SUPPLIED - GENERAL REQUIREMENTS |
| BS ISO 27185:2012 | Cardiac rhythm management devices. Symbols to be used with cardiac rhythm management device labels, and information to be supplied. General requirements |
| ASTM F 3278 : 2017 | Standard Performance Specification for Hand-Held Metal Detectors Used in Safety and Security |
| AAMI PC69 : 2007 | Active implantable medical devices— Electromagnetic compatibility— EMC test protocols for implantable cardiac pacemakers and implantable cardioverter defibrillators American National Standard |
| IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
| ISO/TR 14283:2004 | Implants for surgery — Fundamental principles |
| IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
| ISO 14708-2:2012 | Implants for surgery — Active implantable medical devices — Part 2: Cardiac pacemakers |
| ISO 8601:2004 | Data elements and interchange formats — Information interchange — Representation of dates and times |
| ISO 14708-1:2014 | Implants for surgery — Active implantable medical devices — Part 1: General requirements for safety, marking and for information to be provided by the manufacturer |
| DIN EN 50061 : AMD 1 1996 | SAFETY OF IMPLANTABLE CARDIAC PACEMAKERS |
| ISO 5841-3:2013 | Implants for surgery — Cardiac pacemakers — Part 3: Low-profile connectors (IS-1) for implantable pacemakers |
| ISO 14971:2007 | Medical devices — Application of risk management to medical devices |
| ISO 15223-1:2016 | Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied — Part 1: General requirements |
| ISO 11318:2002 | Cardiac defibrillators — Connector assembly DF-1 for implantable defibrillators — Dimensions and test requirements |
Summarise
US$96.00
Excluding Tax where applicable