ISO 16345:2014
Withdrawn
Water-cooling towers — Testing and rating of thermal performance
Hardcopy , PDF
English
05-27-2014
12-06-2023
ISO 16345:2014 covers the measurement of the thermal performance and pumping head of open- and closed-circuit, mechanical draft, wet and wet/dry cooling towers and natural draft and fan-assisted natural draft, wet and wet/dry cooling towers. The standard rating boundaries for series mechanical draft, open- and closed-circuit cooling towers are specified.
ISO 16345:2014 does not apply to the testing and rating of closed-circuit towers where the process fluid undergoes a change in phase as it passes through the heat exchanger or where the thermophysical properties of the process fluid are not available.
| Committee |
ISO/TC 86/SC 6
|
| DevelopmentNote |
Supersedes ISO/DIS 16345. (05/2014)
|
| DocumentType |
Standard
|
| Pages |
151
|
| ProductNote |
THIS STANDARD ALSO REFERS TO ISO 9551,ISO 10790:1990/Corr.1:2003
|
| PublisherName |
International Organization for Standardization
|
| Status |
Withdrawn
|
| Standards | Relationship |
| NEN ISO 16345 : 2014 | Identical |
| BS ISO 16345:2014 | Identical |
| ISO/TR 15377:2007 | Measurement of fluid flow by means of pressure-differential devices — Guidelines for the specification of orifice plates, nozzles and Venturi tubes beyond the scope of ISO 5167 |
| ISO/TR 12767:2007 | Measurement of fluid flow by means of pressure differential devices — Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167 |
| ISO 5167-3:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 3: Nozzles and Venturi nozzles |
| ISO 7066-2:1988 | Assessment of uncertainty in the calibration and use of flow measurement devices — Part 2: Non-linear calibration relationships |
| ISO 2975-3:1976 | Measurement of water flow in closed conduits — Tracer methods — Part 3: Constant rate injection method using radioactive tracers |
| ISO 13359:1998 | Measurement of conductive liquid flow in closed conduits — Flanged electromagnetic flowmeters — Overall length |
| ISO 2975-7:1977 | Measurement of water flow in closed conduits — Tracer methods — Part 7: Transit time method using radioactive tracers |
| ISO 14511:2001 | Measurement of fluid flow in closed conduits — Thermal mass flowmeters |
| ISO 9300:2005 | Measurement of gas flow by means of critical flow Venturi nozzles |
| ISO 2975-1:1974 | Measurement of water flow in closed conduits — Tracer methods — Part 1: General |
| ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 4: Venturi tubes |
| ASHRAE 41.6 : 2014 | METHOD FOR HUMIDITY MEASUREMENT |
| ISO 9368-1:1990 | Measurement of liquid flow in closed conduits by the weighing method — Procedures for checking installations — Part 1: Static weighing systems |
| ISO 2975-6:1977 | Measurement of water flow in closed conduits — Tracer methods — Part 6: Transit time method using non-radioactive tracers |
| ISO 4677-1:1985 | Atmospheres for conditioning and testing — Determination of relative humidity — Part 1: Aspirated psychrometer method |
| ISO/TR 5168:1998 | Measurement of fluid flow — Evaluation of uncertainties |
| ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 2: Orifice plates |
| ISO 8316:1987 | Measurement of liquid flow in closed conduits — Method by collection of the liquid in a volumetric tank |
| ISO/TR 3313:1998 | Measurement of fluid flow in closed conduits — Guidelines on the effects of flow pulsations on flow-measurement instruments |
| ISO 6817:1992 | Measurement of conductive liquid flow in closed conduits — Method using electromagnetic flowmeters |
| ISO/TR 9464:2008 | Guidelines for the use of ISO 5167:2003 |
| ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 1: General principles and requirements |
| ISO 14164:1999 | Stationary source emissions — Determination of the volume flowrate of gas streams in ducts — Automated method |
| ASTM E 337 : 2015 : REDLINE | Standard Test Method for Measuring Humidity with a Psychrometer (the Measurement of Wet- and Dry-Bulb Temperatures) |
| ISO 10790:2015 | Measurement of fluid flow in closed conduits — Guidance to the selection, installation and use of Coriolis flowmeters (mass flow, density and volume flow measurements) |
| ISO/TR 12764:1997 | Measurement of fluid flow in closed conduits — Flowrate measurement by means of vortex shedding flowmeters inserted in circular cross-section conduits running full |
| ISO 2186:2007 | Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements |
| ISO 11631:1998 | Measurement of fluid flow — Methods of specifying flowmeter performance |
| ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
| ISO 2975-2:1975 | Measurement of water flow in closed conduits — Tracer methods — Part 2: Constant rate injection method using non-radioactive tracers |