ISO 4802-1:2016 specifies:
a) a method for determining the hydrolytic resistance of the interior surfaces of glass containers when subjected to attack by water at 121 °C ± 1 °C for 60 min ± 1 min. The resistance is measured by titration of a known aliquot portion of the extraction solution produced with hydrochloric acid solution, in which case the resistance is inversely proportional to the volume of acid required;
b) a classification of glass containers according to the hydrolytic resistance of the interior surfaces determined by the methods specified in ISO 4802-1:2016.
| Committee |
ISO/TC 76
|
| DevelopmentNote |
Supersedes ISO 4802 (04/2001) Supersedes ISO/DIS 4802-1. (06/2016)
|
| DocumentType |
Standard
|
| Pages |
13
|
| PublisherName |
International Organization for Standardization
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| BS ISO 4802-1:2016 | Identical |
| DIN ISO 4802-1:2016-08 (Draft) | Identical |
| NEN ISO 4802-1 : 2016 | Identical |
| DS ISO 4802-1 : 2016 | Identical |
| IS 2303 : Part 2 : 2018 | Identical |
| DIN ISO 4802-1:2012-12 | Identical |
| NF ISO 4802-1 : 1989 | Identical |
| PN ISO 4802-1 : 1994 | Identical |
| 03/106304 DC : DRAFT APR 2003 | BS ISO 11418-2 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 2: SCREW-NECK BOTTLES FOR SYRUPS |
| 15/30314949 DC : 0 | BS ISO 11418-2 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 2: SCREW-NECK GLASS BOTTLES FOR SYRUPS |
| 15/30314886 DC : 0 | BS ISO 11418-1 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 1: DROP-DISPENSING GLASS BOTTLES |
| 03/106303 DC : DRAFT APR 2003 | BS ISO 11418-1 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 1: DROP-DISPENSING BOTTLES |
| BS 7709-3:1993 | Analysis of extract solutions of glass Method for determination of calcium oxide and magnesium oxide by flame atomic absorption spectrometry |
| BS 7709-5:1993 | Analysis of extract solutions of glass Method for determination of iron (III) oxide by molecular absorption spectrometry and flame atomic absorption spectrometry |
| BS 7709-1:1993 | Analysis of extract solutions of glass Method for determination of silicon dioxide by molecular absorption spectrometry |
| ISO 1135-1:1987 | Transfusion equipment for medical use — Part 1: Glass transfusion bottles, closures and caps |
| NF EN ISO 8362-1 : 2010 AMD 1 2016 | INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING |
| BS EN ISO 9187-1:2010 | Injection equipment for medical use Ampoules for injectables |
| BS EN ISO 8362-1 : 2009 | INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING (ISO 8362-1:2009) |
| DIN ISO 11040-1:2017-07 | PREFILLED SYRINGES - PART 1: GLASS CYLINDERS FOR DENTAL LOCAL ANAESTHETIC CARTRIDGES (ISO 11040-1:2015) |
| 03/106306 DC : DRAFT APR 2003 | BS ISO 11418-4 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 4: TABLET BOTTLES |
| DIN ISO 11040-1:1993-07 | PREFILLED SYRINGES - PART 1: GLASS CYLINDERS FOR DENTAL LOCAL ANAESTHETIC CARTRIDGES (ISO 11040-1:2015) |
| BS ISO 11418-1:2016 | Containers and accessories for pharmaceutical preparations Drop-dispensing glass bottles |
| BS ISO 11040-1:2015 | Prefilled syringes Glass cylinders for dental local anaesthetic cartridges |
| 15/30314850 DC : 0 | BS ISO 11418-7 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 7: SCREW-NECK VIALS MADE OF GLASS TUBING FOR LIQUID DOSAGE FORMS |
| BS ISO 11040-4:2015 | Prefilled syringes Glass barrels for injectables and sterilized subassembled syringes ready for filling |
| BS 7709-6:1993 | Analysis of extract solutions of glass Method for determination of boron (III) oxide by molecular absorption spectrometry |
| ISO 11040-1:2015 | Prefilled syringes — Part 1: Glass cylinders for dental local anaesthetic cartridges |
| ISO 8362-1:2009 | Injection containers and accessories — Part 1: Injection vials made of glass tubing |
| I.S. EN ISO 8536-1:2011 | INFUSION EQUIPMENT FOR MEDICAL USE - PART 1: INFUSION GLASS BOTTLES (ISO 8536-1:2011) |
| I.S. EN ISO 9187-1:2010 | INJECTION EQUIPMENT FOR MEDICAL USE - PART 1: AMPOULES FOR INJECTABLES |
| I.S. EN ISO 8362-4:2011 | INJECTION CONTAINERS AND ACCESSORIES - PART 4: INJECTION VIALS MADE OF MOULDED GLASS (ISO 8362-4:2011) |
| ISO 7348:1992 | Glass containers — Manufacture — Vocabulary |
| BS ISO 7348:1992 | Glass containers. Manufacture. Vocabulary |
| ISO 11418-1:2016 | Containers and accessories for pharmaceutical preparations — Part 1: Drop-dispensing glass bottles |
| 13/30273499 DC : 0 | BS ISO 11040-4 - PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING |
| ISO 11418-3:2016 | Containers and accessories for pharmaceutical preparations — Part 3: Screw-neck glass bottles (veral) for solid and liquid dosage forms |
| BS ISO 11418-3 : 2016 | CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 3: SCREW-NECK GLASS BOTTLES (VERAL) FOR SOLID AND LIQUID DOSAGE FORMS |
| BS ISO 11418-4:2005 | Containers and accessories for pharmaceutical preparations Tablet glass bottles |
| ISO 11418-7:2016 | Containers and accessories for pharmaceutical preparations — Part 7: Screw-neck vials made of glass tubing for liquid dosage forms |
| BS 7709-4:1993 | Analysis of extract solutions of glass Method for determination of aluminium oxide by molecular absorption spectrometry |
| DIN EN ISO 8362-1:2016-06 | INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING (ISO 8362-1:2009 + AMD 1:2015) |
| ISO 11418-2:2016 | Containers and accessories for pharmaceutical preparations — Part 2: Screw-neck glass bottles for syrups |
| ISO 9187-1:2010 | Injection equipment for medical use — Part 1: Ampoules for injectables |
| BS ISO 11418-7:2016 | Containers and accessories for pharmaceutical preparations Screw-neck vials made of glass tubing for liquid dosage forms |
| ISO 11418-4:2005 | Containers and accessories for pharmaceutical preparations — Part 4: Tablet glass bottles |
| 03/106305 DC : DRAFT APR 2003 | BS ISO 11418-3 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 3: SCREW-NECK BOTTLES (VERAL) FOR SOLID AND LIQUID DOSAGE FORMS |
| BS 7709-2:1993 | Analysis of extract solutions of glass Method for determination of sodium oxide and potassium oxide by flame spectrometric methods |
| ISO 12775:1997 | Guidelines on types of glass of normal bulk-production composition and their test methods |
| DIN EN ISO 9187-1:2011-01 | Injection equipment for medical use - Part 1: Ampoules for injectables (ISO 9187-1:2010) |
| ISO 11040-4:2015 | Prefilled syringes — Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling |
| DIN EN ISO 8536-1:2011-12 | Infusion equipment for medical use - Part 1: Infusion glass bottles (ISO 8536-1:2011) |
| DIN EN ISO 8362-4:2011-12 | Injection containers and accessories - Part 4: Injection vials made of moulded glass (ISO 8362-4:2011) |
| BS EN 28362-4:1993 | Injection containers for injectables and accessories Injection vials made of moulded glass |
| BS EN ISO 8536-1:2011 | Infusion equipment for medical use Infusion glass bottles |
| BS EN ISO 8362-4:2011 | Injection containers and accessories Injection vials made of moulded glass |
| ISO 8536-1:2011 | Infusion equipment for medical use — Part 1: Infusion glass bottles |
| EN ISO 8362-4:2011 | Injection containers and accessories - Part 4: Injection vials made of moulded glass (ISO 8362-4:2011) |
| EN ISO 9187-1:2010 | Injection equipment for medical use - Part 1: Ampoules for injectables (ISO 9187-1:2010) |
| EN ISO 8536-1:2011 | Infusion equipment for medical use - Part 1: Infusion glass bottles (ISO 8536-1:2011) |
| 14/30310712 DC : 0 | BS ISO 11040-1 - PREFILLED SYRINGES - PART 1: GLASS CYLINDERS FOR DENTAL LOCAL ANAESTHETIC CARTRIDGES |
| 15/30314952 DC : 0 | BS ISO 11418-3 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 3: SCREW-NECK GLASS BOTTLES (VERAL) FOR SOLID AND LIQUID DOSAGE FORMS |
| BS ISO 12775:1997 | Guidelines on types of glass of normal bulk-production composition and their test methods |
| DIN ISO 11040-4:2007-10 | PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING (ISO 11040-4:2015) |
| BS 3473-4.2:1989 | Chemical resistance of glass used in the production of laboratory glassware. Methods for determination of hydrolytic resistance ofthe interior surfaces of glass containers Determination by flame photometry and classification |
| BS ISO 11418-2 : 2016 | CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 2: SCREW-NECK GLASS BOTTLES FOR SYRUPS |
| ISO 13926-1:2004 | Pen systems — Part 1: Glass cylinders for pen-injectors for medical use |
| I.S. EN ISO 8362-1:2009 | INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING (ISO 8362-1:2009) |
| DIN ISO 11040-4:2017-07 | Prefilled syringes - Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling (ISO 11040-4:2015) |
| UNE-EN ISO 9187-1:2011 | Injection equipment for medical use - Part 1: Ampoules for injectables (ISO 9187-1:2010) |
| UNE-EN ISO 8536-1:2012 | Infusion equipment for medical use - Part 1: Infusion glass bottles (ISO 8536-1:2011) |
| UNE-EN ISO 8362-4:2012 | Injection containers and accessories - Part 4: Injection vials made of moulded glass (ISO 8362-4:2011) |
| UNE-EN ISO 8362-1:2010 | Injection containers and accessories - Part 1: Injection vials made of glass tubing (ISO 8362-1:2009) |
| ISO 11040-4:2015 | Prefilled syringes — Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling |
| ISO 13926-1:2004 | Pen systems — Part 1: Glass cylinders for pen-injectors for medical use |
| ISO 385:2005 | Laboratory glassware — Burettes |
| ISO 720:1985 | Glass — Hydrolytic resistance of glass grains at 121 degrees C — Method of test and classification |
| ISO 3585:1998 | Borosilicate glass 3.3 — Properties |
| ISO 648:2008 | Laboratory glassware — Single-volume pipettes |
| ISO 3819:2015 | Laboratory glassware — Beakers |
| ISO 1773:1997 | Laboratory glassware — Narrow-necked boiling flasks |
| ISO 8362-4:2011 | Injection containers and accessories — Part 4: Injection vials made of moulded glass |
| ISO 8362-1:2009 | Injection containers and accessories — Part 1: Injection vials made of glass tubing |
| ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
| ISO 11418-1:2016 | Containers and accessories for pharmaceutical preparations — Part 1: Drop-dispensing glass bottles |
| ISO 11418-4:2005 | Containers and accessories for pharmaceutical preparations — Part 4: Tablet glass bottles |
| ISO 11040-1:2015 | Prefilled syringes — Part 1: Glass cylinders for dental local anaesthetic cartridges |
| ISO 719:1985 | Glass — Hydrolytic resistance of glass grains at 98 degrees C — Method of test and classification |
| ISO 9187-1:2010 | Injection equipment for medical use — Part 1: Ampoules for injectables |
| ISO 11418-7:2016 | Containers and accessories for pharmaceutical preparations — Part 7: Screw-neck vials made of glass tubing for liquid dosage forms |
| ISO 8536-1:2011 | Infusion equipment for medical use — Part 1: Infusion glass bottles |