ISO 80601-2-13:2011

Withdrawn

Withdrawn

View Superseded by

Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation

Available format(s)

Hardcopy , PDF

Published date

08-08-2011

Withdrawn date

04-09-2025

Superseded by

ISO 80601-2-13:2022

US$96.00
Excluding Tax where applicable
Summarise this standard

ISO/IEC 80601-2-13:2011 is applicable to the basic safety and essential performance of an anaesthetic workstation for administering inhalational anaesthesia whilst continuously attended by a professional operator.

ISO/IEC 80601-2-13:2011 specifies particular requirements for a complete anaesthetic workstation and the following anaesthetic workstation components which, although considered as individual devices in their own right, may be utilized, in conjunction with other relevant anaesthetic workstation components, to form an anaesthetic workstation to a given specification:

  • anaesthetic gas delivery system;
  • anaesthetic breathing system;
  • anaesthetic gas scavenging system;
  • anaesthetic vapour delivery system;
  • anaesthetic ventilator;
  • monitoring equipment;
  • alarm system;
  • protection device.

ISO/IEC 80601-2-13:2011 is also applicable to those accessories intended by their manufacturer to be connected to an anaesthetic workstation where the characteristics of those accessories can affect the basic safety and essential performance of the anaesthetic workstation.

If a clause or subclause is specifically intended to be applicable to anaesthetic workstation components only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to an anaesthetic workstation and its individual components, as relevant.

Hazards inherent in the intended physiological function of an anaesthetic workstation and its individual components within the scope of ISO/IEC 80601-2-13:2011 are not covered by specific requirements in ISO/IEC 80601-2-13:2011 except in 7.2.13 and 8.4.1 of IEC 60601-1:2005.

ISO/IEC 80601-2-13:2011 is not applicable to any anaesthetic workstation intended for use with flammable anaesthetic agents, as determined by Annex BB.

Committee
ISO/TC 121/SC 1
DevelopmentNote
Supersedes ISO/DIS 80601-2-13, ISO 8835-2, ISO 8835-3, ISO 8835-4 and ISO 8835-5. (08/2011) Supersedes IEC 60601-2-13. (04/2016)
DocumentType
Standard
Pages
99
ProductNote
THIS STANDARD ALSO REFERS TO IEC 61010.
PublisherName
International Organization for Standardization
Status
Withdrawn
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

US$96.00
Excluding Tax where applicable