1 SCOPE
2 APPLICABLE DOCUMENTS
3 REQUIREMENTS
4 QUALITY ASSURANCE PROVISIONS
5 PACKAGING
6 NOTES
Describes mechanical water cooling units for bakeries.
| DevelopmentNote |
E NOTICE 1 - Notice of Cancellation without replacement. (06/2004)
|
| DocumentType |
Standard
|
| Pages |
22
|
| PublisherName |
US Military Specs/Standards/Handbooks
|
| Status |
Withdrawn
|
This document covers mechanical water cooling units for bakeries.
| MIL STD 773 : C NOTICE 3 | COMPRESSOR, HERMETIC, FOR USE WITH REFRIGERANT 12 |
| MS35869 Revision C:1975 | ADAPTER, STRAIGHT, MALE, REFRIGERATION PIPE TO FLARED TUBE (S/S BY SAE-J513) |
| MS35928 Revision C:1975 | ELBOW, TUBE, STREET, 90 AND 45 DEGREE, SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59450) |
| MIL-C-3774 Revision B:1991 | Crates, Wood: Open 12,000- and 16,000-Pound Capacity (S/S by ASTM-D7478/D7478D) |
| MIL-V-13811 Revision D:1976 | Varnish, Waterproofing, Electrical, Ignition (No S/S Document) |
| MIL-STD-129 Revision R:2014 | Military Marking for Shipment and Storage |
| MS35873 Revision C:1975 | CONNECTION, END, EXTERNAL FLARE, REFRIGERATION (S/S BY SAE-J513) |
| MS35868 Revision B:1970 | CONNECTION, END, EXTERNAL PIPE THREAD REFRIGERATION (S/S BY SAE-J513) |
| MS25917 Revision H:2011 | Relays, Electromagnetic, 3 Amperes, 4 PDT, Type I |
| MS35871 Revision C:1978 | TEE, PIPE TO TUBE, REFRIGERATION (S/S BY SAE-J513) |
| MIL-STD-130 Revision N:2007 | Identification Marking of U.S. Military Property |
| NEMA MG 1 : 2016 | MOTORS AND GENERATORS |
| MIL-STD-1186 Revision A:1981 | CUSHIONING, ANCHORING, BRACING, BLOCKING AND WATERPROOFING; WITH APPROPRIATE TEST METHODS (NO S/S DOCUMENT) |
| MS35927 Revision C:1975 | COUPLING, TUBE, WITH STOP, SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59449) |
| MS27900 Revision C:1985 | GAGES, PRESSURE AND GAGES COMPOUND, PRESSURE AND VACUUM, DIAL INDICATING, PANEL MOUNTED, 2 1/2 INCH DIAL SIZE, REFRIGERANT R12 AND R22 (NO S/S DOCUMENT) |
| ASHRAE 30 : 2017 | METHOD OF TESTING LIQUID CHILLERS |
| MS 17797 : C | VALVE, REGULATING, FLUID PRESSURE, (WATER) REFRIGERANT-12 |
| MS17982 Revision D:2005 | Valves, Expansion, Thermostatic, Refrigerant-12 (R-12) and Refrigerant-22 (R-22) |
| MS35924 Revision B:1975 | PLUG AND CAP, TUBE, SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59448) |
| MS17798 Revision D:1975 | INDICATOR, SIGHT, LIQUID, REFRIGERANT (NO S/S DOCUMENT) |
| MIL P 15024 : E | PLATES, TAGS AND BANDS FOR IDENTIFICATION OF EQUIPMENT |
| PPP-T-60 Revision E:1986 | Tape: Packaging, Waterproof (S/S by ASTM D5486/ASTM-D5486M) |
| MS35872 Revision C:1978 | FLARE NUT AND FLARE SEAL BONNET, REFRIGERATION (S/S BY SAE-J513) |
| MS35929 Revision C:1972 | TEE, TUBE, STRAIGHT, SOLDER JOINT, REFRIGERATION (S/S BY A-A-59451) |
| MS35926 Revision C:1970 | CONNECTION END, INTERNAL PIPE THREAD, REFRIGERATION (S/S BY SAE-J513) |
| MS35867 Revision C:1970 | CONNECTION END, INTERNAL FLARE, REFRIGERATION (S/S BY SAE-J513) |
| MIL-STD-759 Revision B:1970 | CONDENSER, AIR COOLED, REFRIGERANT-12 (NO S/S DOCUMENT) |
| MS35925 Revision B:1988 | CONNECTION END, SOLDER-JOINT, REFRIGERATION (S/S BY ASME-ANSI-B16.22) |
| MIL-STD-461 Revision G:2015 | Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment |
| MS35921 Revision C:1976 | ADAPTER, STRAIGHT, PIPE TO TUBE, PIPE THD TO FEMALE SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59445) |
| MS35918 Revision B:1972 | ADAPTER, STRAIGHT, PIPE THREAD TO TUBE, MALE SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59443) |
| TT-P-664 Revision D:1988 | PRIMER COATING, ALKYD, CORROSION-INHIBITING, LEAD AND CHROMATE FREE, VOC-COMPLIANT (S/S BY SSPC-PAINT25) |
| MS35922 Revision C:1975 | ELBOW, TUBE, 90 DEGREE, REDUCING, SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59446) |
| MS35845 Revision F:2010 | Dehydrators, Desiccant, Refrigerant-12 |
| MIL-P-116 Revision J:1988 | PRESERVATION, METHODS OF (S/S BY MIL-STD-2073-1) |
| MS35920 Revision C:1976 | REDUCER COUPLING, TUBE, MALE TO FEMALE SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59444) |
| BB-F-1421 Revision B:1982 | Fluorocarbon Refrigerants (S/S by A-A-58060) |
| MS27211 Revision D:1994 | THERMOMETER, INDICATING, CAPILLARY TUBE AND BULB, 2-1/2 INCH DIAL SIZE (NO S/S DOCUMENT) |
| MS35923 Revision C:1975 | REDUCER COUPLING, TUBE, FEMALE TO FEMALE SOLDER-JOINT, REFRIGERATION (S/S BY A-A-59447) |
| MS35919 Revision C:1975 | ADAPTER, STRAIGHT, PIPE TO TUBE, EXTERNAL FLARE TO FEMALE SOLDER-JOINT, REFRIGERATION (S/S BY SAE-J513) |
| MS35881 Revision C:1978 | Valve, Packless, Stop, Flare Connection Ends (No S/S Document) |
| MIL STD 279 : B NOTICE 3 | COMPRESSOR, RECIPROCATING, POWER DRIVEN, OPEN-TYPE, FOR USE WITH REFRIGERANT - 12 |
| ASTM D 1621 : 2016 : REDLINE | Standard Test Method for Compressive Properties of Rigid Cellular Plastics |
| FED-STD-H28 Revision A:1994 | Screw-Thread Standards for Federal Services |
| ASHRAE 15 : 2013 | SAFETY STANDARD FOR REFRIGERATION SYSTEMS |
| MIL-STD-105 Revision E:1989 | Sampling Procedures and Tables for Inspection by Attributes (See Notice 3 for Replacement Information) |
| MS35870 Revision C:1975 | ADAPTER, REFRIGERANT CYLINDER, EXTERNAL FLAREX STRAIGHT PIPE, REFRIGERATION (S/S BY SAE-J513) |
| MS35882 Revision C:1978 | VALVE, PACKLESS, STOP, THREE-WAY, SOLDER-JOINT CONNECTION ENDS (NO S/S DOCUMENT) |
| MS49008 Revision B:1975 | Tee, Tube, Flare Connection, Refrigeration (S/S by SAE-J513) |
| MS 17291 : C | RECEIVER LIQUID REFRIGERANT 12 |
| MS35880 Revision C:1978 | VALVE, PACKLESS STOP, SOLDER-JOINT CONNECTION ENDS (NO S/S DOCUMENT) |
| MIL-C-104 Revision C:1992 | Crates, Wood: Lumber and Plywood Sheathed, Nailed, and Bolted (S/S by ASTM-D7478/D7478M) |
Summarise
US$20.00
Excluding Tax where applicable