NFPA 231C : 1998
Withdrawn
View Superseded by
RACK STORAGE OF MATERIALS
01-12-1998
09-01-1999
Chapter 1 - Introduction
1-1 Application and scope
1-2 Definitions
Chapter 2 - Classification of storage
2-1 Commodity classifications
Chapter 3 - Building construction
3-1 Construction
3-2 Fire protection of steel
3-3 Vents and draft curtains
Chapter 4 - Storage arrangements
4-1 Rack structure
4-2 Rack space
4-3 Flue space
4-4 Aisle widths
4-5 Storage heights
4-6 Commodity clearances
4-7 Storage of idle combustible pallets
Chapter 5 - Fire protection - general
5-1 Protection systems
5-2 Ceiling sprinklers
5-3 Ceiling sprinkler spacing
5-4 In-rack sprinkler system size
5-5 In-rack sprinkler system control valves
5-6 In-rack sprinkler water demand
5-7 Sprinkler waterflow alarm
5-8 Hose connections
5-9 Hose demand
5-10 Duration of water supplies
5-11 High expansion foam
5-12 Detectors for high expansion foam systems
5-13 Solid and slatted shelves
5-14 Open-top combustible containers
5-15 Movable racks
Chapter 6 - Fire protection - storage up to and
including 25 feet (7.62 m) in height
Part A - General
6-1 General
6-2 In-rack sprinkler type
6-3 In-rack sprinkler pipe size
6-4 In-rack sprinkler water shields
6-5 In-rack sprinkler location
6-6 In-rack sprinkler spacing
6-7 In-rack sprinkler discharge pressure
6-8 In-rack sprinkler water demand
6-9 Ceiling sprinkler water demand
6-10 High expansion foam submergence
6-11 High expansion foam ceiling sprinkler density
Part B - Double and single row racks
6-12 Ceiling sprinkler water demand
6-13 In-rack sprinkler location
Part C - Multiple row racks
6-14 In-rack sprinkler location
6-15 Ceiling sprinkler water demand
Chapter 7 - Fire protection - storage over 25 feet
(7.62 m) in height
Part A - General
7-1 In-rack sprinkler type
7-2 In-rack sprinkler spacing
7-3 In-rack sprinkler pipe size
7-4 In-rack sprinkler water shields
7-5 In-rack sprinkler location
7-6 In-rack sprinkler discharge pressure
7-7 In-rack sprinkler water demand
7-8 High expansion foam submergence
7-9 High expansion foam - ceiling sprinkler water
demand
Part B - Double and single row racks
7-10 In-rack sprinkler location
7-11 In-rack sprinkler horizontal barriers
7-12 Ceiling sprinkler water demand
Part C - Multiple row racks
7-13 In-rack sprinkler location
7-14 In-rack sprinkler spacing
7-15 Ceiling sprinkler water demand
Chapter 8 - Plastics
8-1 General
8-2 Single, double, and multiple-row racks -
Storage up to and including 25 ft (7.6m) -
Clearances up to and including 10 ft (3.1m)
8-3 Single and double row racks - storage over
25 ft (7.7 m) in height
Chapter 9 - Large-drop sprinklers
9-1 General
Chapter 10 - Early suppression fast response (ESFR)
sprinklers
10-1 General
10-2 Sprinkler system design
10-3 Water demand
Chapter 11 - Equipment
11-1 Mechanical handling equipment - Industrial
trucks
Chapter 12 - Building maintenance and operation
12-1 Building operations other than storage
12-2 Waste disposal
12-3 Smoking
12-4 Maintenance
12-5 Plant emergency organization
12-6 General fire protection
Chapter 13 - Referenced publications
Appendix A - Explanatory material
Appendix B - Explanation of test data and procedures
Appendix C - Referenced publications
Index
Applies to the broad range of combustibles stored over 12 feet in height on racks, covering standard building construction, storage arrangements, fire protection, and building maintenance.
| DevelopmentNote |
Incorporated into the revision redesignated NFPA 230 and withdrawn
|
| DocumentType |
Standard
|
| PublisherName |
National Fire Protection Association
|
| Status |
Withdrawn
|
| SupersededBy |
| NFPA 231F : 1996 | STORAGE OF ROLL PAPER |
| NFPA 419 : 1992 | MASTER PLANNING AIRPORT WATER SUPPLY SYSTEMS FOR FIRE PROTECTION |
| NFPA 651 : 1998 | MACHINING AND FINISHING OF ALUMINUM AND THE PRODUCTION AND HANDLING ALUMINUM POWDERS |
| NFPA 11A : 1999 | MEDIUM- AND HIGH-EXPANSION FOAM SYSTEMS |
| NFPA 231E : 1996 | STORAGE OF BALED COTTON |
| NFPA 43A : 1990 | STORAGE OF LIQUID AND SOLID OXIDIZERS |
| NFPA 43D : 1994 | STORAGE OF PESTICIDES |
| NFPA 13A : 1987 | INSPECTION, TESTING, AND MAINTENANCE OF SPRINKLER SYSTEMS |
| NFPA 231D : 1998 | STORAGE OF RUBBER TIRES |
| ANSI L1.1 : 1981 | SAFETY AND HEALTH REQUIREMENTS FOR THE TEXTILE INDUSTRY, |
| NFPA 43B : 1993 | STORAGE OF ORGANIC PEROXIDE FORMULATIONS |
| NFPA 72E : 1990 | AUTOMATIC FIRE DETECTORS |
| NFPA 231 : 1998 | GENERAL STORAGE |
| NFPA 30 FRENCH : 1996 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
| NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
| NFPA 231F : 1996 | STORAGE OF ROLL PAPER |
| NFPA 232 : 2017 | PROTECTION OF RECORDS |
| NFPA 25 : 2017 | INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS |
| NFPA 58 : 2017 | LIQUEFIED PETROLEUM GAS CODE |
| NFPA 505 : 2013 | FIRE SAFETY STANDARD FOR POWERED INDUSTRIAL TRUCKS INCLUDING TYPE DESIGNATIONS, AREAS OF USE, CONVERSIONS, MAINTENANCE, AND OPERATIONS |
| NFPA 231D : 1998 | STORAGE OF RUBBER TIRES |
| NFPA 81 : 1986 | FUR STORAGE, FUMIGATION AND CLEANING |
| NFPA 220 : 2018 | TYPES OF BUILDING CONSTRUCTION |
| NFPA 231 : 1998 | GENERAL STORAGE |
| NFPA 51B : 2014 | FIRE PREVENTION DURING WELDING, CUTTING, AND OTHER HOT WORK |
| NFPA 231E : 1996 | STORAGE OF BALED COTTON |
| NFPA 72 : 2016 | NATIONAL FIRE ALARM AND SIGNALING CODE |
| NFPA 13 : 2016 | INSTALLATION OF SPRINKLER SYSTEMS |
| NFPA 40 : 2016 | STORAGE AND HANDLING OF CELLULOSE NITRATE FILM |
| NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
| NFPA 490 : 2002 | CODE FOR THE STORAGE OF AMMONIUM NITRATE |
| NFPA 82 : 2014 | INCINERATORS AND WASTE AND LINEN HANDLING SYSTEMS AND EQUIPMENT |
| NFPA 11A : 1999 | MEDIUM- AND HIGH-EXPANSION FOAM SYSTEMS |