NFPA 72H : 1988

Superseded

Superseded

View Superseded by

TESTING PROCEDURES FOR LOCAL, AUXILIARY, REMOTE STATION, AND PROPRIETARY PROTECTIVE SIGNALING SYSTEMS

Published date

01-12-2013

Superseded date

07-23-2013

Superseded by

NFPA 72 : 2016

Sorry this product is not available in your region.
Summarise this standard

Chapter 1 General
1.1 Scope
1.2 Definitions
1.3 Fire Alarm System Certification and Description
      Document
Chapter 2 Acceptance and Reacceptance Testing Procedures
2.1 General
2.2 Installation Testing
2.3 System Testing
2.4 Reacceptance Testing
Chapter 3 Periodic Equipment and Circuit Testing
           Procedures
3.1 Periodic Testing
Chapter 4 Recommended Schedules and Methods for Testing
           Procedures
4.1 General
Chapter 5 Procedure for Testing Systems Equipped with
           Alarm Verification
Chapter 6 Multiplex System Testing Procedures
Chapter 7 Typical Circuit Wiring Diagrams
7.1
7.2 Diagram of Nonpowered Alarm or Supervisory
      Initiating Devices (e.g. Manual Station or Valve
      Supervisory Switch) Connected to Style A, B, or C
      Initiating Device Circuits
7.3 Diagram of Nonpowered Alarm or Supervisory
      Initiating Devices Connected to Style D or E
      Initiating Device Circuits
7.4 Diagram of Circuit-Powered (2-Wire) Smoke Detectors
      for Style A, B, or C Initiating Device Circuits
7.5 Diagram of Circuit-Powered (2-Wire) Smoke Detectors
      for Style D or E Initiating Device Circuits
7.6 Diagram of Combination Alarm Initiating Device and
      Indicating Appliance Circuits
7.7 Diagram of Combination Alarm Initiating Device and
      Indicating Circuits Arranged for Operation with a
      Single Open or Ground Fault
7.8 Diagram of Style A, B, or C Circuits with 4-Wire
      Smoke Detectors and an End-of-Line Power Supervision
      Relay
7.9 Diagram of Style A, B, or C Initiating Device
      Circuits with 4-Wire Smoke Detectors that Include
      Integral Individual Supervision Relays
7.10 Diagrams of Alarm Indicating Appliances
7.11 Diagram of System with a Supervised Audible
      Indicating Appliance Circuit and an Unsupervised
      Visible Indicating Appliance Circuit
7.12 Diagram of System with Supervised Audible and
      Visible Indicating Appliance Circuits
7.13 Diagram of Series Indicating Appliance Circuit,
      which No Longer Meets the Requirements of NFPA 72A,
      NFPA 72D, and NFPA 72F
7.14 Diagram of Supervised Series Supervisory Initiating
      Circuit with Sprinkler Supervisory Valve Switches
      Connected, which No Longer Meets the Requirements
      of NFPA 72A, NFPA 72D, and NFPA 72F
7.15 Diagram of Initiating Device Circuit with Parallel
      Waterflow Alarm Switches and a Series Supervisory
      Valve Switch, which No Longer Meets the Requirements
      of NFPA 72A, NFPA 72D, or NFPA 72F
7.16 Diagram of an Auxiliary Circuit Connected to a
      Municipal Fire Alarm Master Box
7.17 Diagram of Door Hold and Release Unit with
      Unsupervised Wiring
7.18 Diagram of Remote Relays Connected to an
      Unsupervised Indicating Appliance Circuit
Chapter 8 Referenced Publications
Index

Provides procedures for acceptance and periodic testing of installed protective signaling systems.

DocumentType
Standard
PublisherName
National Fire Protection Association
Status
Superseded
SupersededBy

Sorry this product is not available in your region.