PD CLC/TR 61340-5-2:2008
Superseded
View Superseded by
Electrostatics Protection of electronic devices from electrostatic phenomena. User guide
Hardcopy , PDF
English
06-30-2011
04-30-2018
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 ESD control program plan
4.1 Developing an ESD control program plan
4.1.1 Assignment of an ESD coordinator
4.1.2 Determination of part ESD sensitivity
4.1.3 Initial process and organizational assessment
4.1.4 Documentation of ESD control program plan
4.1.5 Tailoring
4.2 Development of a training plan
4.2.1 Personnel training
4.3 Development of a compliance verification plan
4.3.1 Introduction
4.3.2 ESD control items
4.3.3 Verification frequency
4.3.4 Type of verifications
4.3.5 ESD control item limits
4.3.6 Test methods
4.3.7 Test equipment
4.3.8 Auditor skills
4.3.9 Reporting of audit findings
4.4 Grounding/bonding systems
4.4.1 Introduction
4.4.2 Basic grounding requirements
4.4.3 Additional grounding considerations
4.4.4 Verification of ESD grounding system
4.4.5 Verification of proper installation of ESD
control items
4.5 Personnel grounding
4.5.1 System requirements
4.5.2 Wrist strap system
4.5.3 Footwear-flooring system
4.6 Protected areas (EPA)
4.7 ESD control items
4.7.1 Work surfaces
4.7.2 Wrist straps
4.7.3 Static protective floor materials
4.7.4 Footwear
4.7.5 Static protective seating
4.7.6 Ionization
4.7.7 Garments
4.7.8 Storage racks and shelving
4.7.9 Mobile equipment
4.8 Packaging electronic products for shipment and storage
4.8.1 Introduction and purpose
4.8.2 Definitions
4.8.3 Selecting/designing the right package
4.9 Marking
4.9.1 Marking of assemblies and equipment
4.9.2 Marking of packaging
4.9.3 Other marking considerations
Annex A (informative) Example ESD control document based on
IEC 61340-5-1
Annex B (informative) ESD control element considerations
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Specifies to protect devices that are susceptible to discharges of 100 V or greater using the human body model test method.
| Committee |
GEL/101
|
| DevelopmentNote |
Supersedes BS EN 61340-5-2 and 05/30127522 DC. (06/2008)
|
| DocumentType |
Standard
|
| Pages |
76
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This technical report has been developed to support IEC 61340-5-1.
The controls and limits referenced in this standard were developed to protect devices that are susceptible to discharges of 100 V or greater using the human body model test method. However, the general concepts are still valid for devices that are susceptible to discharges of less than 100 V.
| Standards | Relationship |
| CLC/TR 61340-5-2:2008 | Identical |
| IEC TR 61340-5-2:2007 | Identical |
A newer version of this standard is available.
View Current Edition