PD CR 12471:2002
Superseded
View Superseded by
Screening tests for nickel release from alloys and coatings in items that come into direct and prolonged contact with the skin
Hardcopy , PDF
English
09-30-2002
03-11-2022
Foreword
Introduction
1 Scope
2 Short description of the methods
3 Reagents
4 Equipment
5 Procedure
5.1 Preparation of solutions
5.2 Sample preparation
5.3 Test methods
6 Interpretation of results
6.1 Positive result
6.2 Negative result
6.3 Uncertain result
7 Test report
Bibliography
Gives a screening procedure, based primarily on the use of dimethylglyoxime, for the detection of nickel release from items that come into direct and prolonged contact with the skin.
| Committee |
STI/53
|
| DevelopmentNote |
Supersedes 96/123901 DC (10/2002)
|
| DocumentType |
Standard
|
| Pages |
14
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| CR 12471:2002 | Identical |
| EN 1810 : 1998 | BODY-PIERCING POST ASSEMBLIES - REFERENCE TEST METHOD FOR DETERMINATION OF NICKEL CONTENT BY FLAME ATOMIC ABSORPTION SPECTROMETRY |
| EN 1811:2011+A1:2015 | Reference test method for release of nickel from all post assemblies which are inserted into pierced parts of the human body and articles intended to come into direct and prolonged contact with the skin |