PREN 6059-406 : 200P2
Withdrawn
Withdrawn
View Superseded by
AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVES - TEST METHODS - PART 406: VIBRATION
Available format(s)
Hardcopy , PDF
Language(s)
English
Withdrawn date
12-21-2023
Superseded by
US$125.15
Excluding Tax where applicable
Foreword
1 Scope
2 Normative references
3 Preparation of specimens
4 Apparatus
5 Test methods
6 Requirements
Describes the method and means required for testing the vibration resistance of protection sleeve for electrical cable and cable bundles for aerospace application.
| DevelopmentNote |
To be read in conjunction with PREN 6059-100. (08/2003)
|
| DocumentType |
Draft
|
| Pages |
10
|
| ProductNote |
Superseded by EN 6059-406:2014
|
| PublisherName |
Aerospace & Defence Industries Association of Europe
|
| Status |
Withdrawn
|
| SupersededBy |
| Standards | Relationship |
| DIN EN 6059-406:2014-07 | Identical |
| NF EN 6059-406 : 2015 | Identical |
| 12/30259525 DC : 0 | Identical |
| PREN 6049-009 : 200P3 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 009: SELF-WRAPPING FIRE PROTECTION SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD |
| I.S. EN 6049-007:2012 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 007: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 D EGREES C TO 260 DEGREES C - PRODUCT STANDARD |
| PREN 6049-006 : 200P4 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 006: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION - PRODUCT STANDARD |
| BS EN 6049-007:2012 | Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Self-wrapping mechanical and electrical protective sleeve, flexible post installation operating temperature from -55°C to 260°C. Product standard |
| 12/30275061 DC : 0 | BS EN 6049-009 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTIVE SLEEVE IN ARAMID FIBRES - PART 009: SELF WRAPPING FIRE PROTECTION SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD |
| PREN 4674-001 : DRAFT 2015 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 001: TECHNICAL SPECIFICATION |
| PREN 4674-004 : 200P1 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 004: OPEN SLEEVE - OUTSIDE PRESSURIZED AREA - EMI PROTECTION 10 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
| EN 6049-001:2015 | Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 001: Technical specification |
| 15/30334224 DC : 0 | BS EN 6049-008 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION, PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 008: SELF-WRAPPING SHIELDED (EMI) PROTECTIVE SLEEVE WITH NICKEL COPPER BRAID, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREE C TO 200 DEGREE C - PRODUCT STANDARD |
| BS EN 6049-001:2015 | Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Technical specification |
| 08/30185299 DC : DRAFT JULY 2008 | BS EN 6049-006 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 006: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION - PRODUCT STANDARD |
| 15/30322426 DC : 0 | BS EN 6049-001 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 001: TECHNICAL SPECIFICATION |
| 14/30314814 DC : 0 | BS EN 4674-001 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 001: TECHNICAL SPECIFICATION |
| 15/30322162 DC : 0 | BS EN 4674-003 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 003: OPEN SLEEVE - INSIDE PRESSURIZED AREA - EMI PROTECTION 5 KA TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
| 12/30271082 DC : 0 | BS EN 6049-001 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 001: TECHNICAL SPECIFICATION |
| 12/30263294 DC : 0 | BS EN 6059-100 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVES - TEST METHODS - PART 100: GENERAL |
| EN 6049-006:2012 | Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 006: Self-wrapping protective sleeve, flexible post installation - Product standard |
| EN 6049-007:2012 | Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 007: Self-wrapping mechanical and electrical protective sleeve, flexible post installation operating temperature from - 55 °C to 260 °C - Product standard |
| PREN 4674-003 : 200P2 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 003: OPEN SLEEVE - INSIDE PRESSURIZED AREA - EMI PROTECTION 5 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
| PREN 6049-007 : 200P1 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 007: SELF-WRAPPING MECHANICAL AND ELECTRICAL PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD |
| I.S. EN 6049-001:2015 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 001: TECHNICAL SPECIFICATION |
| I.S. EN 6049-006:2012 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 006: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION - PRODUCT STANDARD |
| 08/30192674 DC : 0 | BS EN 6059-100 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVES - TEST METHODS - PART 100: GENERAL |
| BS EN 6049-006:2012 | Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Self-wrapping protective sleeve, flexible post installation. Product standard |
| EN 6059-100:2015 | Aerospace series - Electrical cables, installation - Protection sleeves - Test methods - Part 100: General |
| EN 3838:2010 | Aerospace series - Requirements and tests on user-applied markings on aircraft electrical cables |
| SAE AS23190C | Wiring, Positioning, and Support Accessories |
| MS21919 Revision E:1981 | Clamp, Loop Type, Cushioned, Support |
| PREN 2266-004 : 200P1 | AEROSPACE SERIES - CABLES, ELECTRICAL, FOR GENERAL PURPOSE - OPERATING TEMPERATURES BETWEEN -55 DEGREES C AND 200 DEGREES C - PART 004: CO[2] LASER PRINTABLE - PRODUCT STANDARD |
| EN 2267-010:2017 | Aerospace series - Cables, electrical, for general purpose - Operating temperatures between -55 °C and 260 °C - Part 010: DR family, single UV laser printable - Product standard |
| ISO 7137:1995 | Aircraft — Environmental conditions and test procedures for airborne equipment |
| MIL-DTL-85052 Revision B:2005 | Clamp, Loop, Cushion, General Specification for |
Summarise
US$125.15
Excluding Tax where applicable