UNE-EN 55011:2011
Withdrawn
Withdrawn
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
Available format(s)
Hardcopy , PDF
Published date
03-23-2011
Publisher
Withdrawn date
02-16-2019
US$136.02
Excluding Tax where applicable
| Committee |
CTN 208/SCCISPR
|
| DevelopmentNote |
Supersedes UNE 20506. (03/2000)
|
| DocumentType |
Standard
|
| Pages |
67
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Withdrawn
|
| Standards | Relationship |
| DIN EN 55011 : 2011 | Identical |
| EN 55011:2009/A1:2010 | Identical |
| NBN EN 55011 : 2016 | Identical |
| EN 55011:2009 | Identical |
| I.S. EN 55011:2016 | Identical |
| NF EN 55011 : 2016 AMD 1 2017 | Identical |
| CISPR 11:2015 RLV | Identical |
| NEN EN 55011 : 2016 AMD 1 2017 | Identical |
| BS EN 55011 : 2016 | Identical |
| EN 55011:2016/A1:2017 | Identical |
| CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
| EN 62135-2:2015 | Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
| CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
| EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
| EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
| CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
| IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
| IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
| CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
| IEC TR 60083:2015 | Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC |
| IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
| IEC 61922:2002 | High-frequency induction heating installations - Test methods for the determination of power output of the generator |
| CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
| IEC 60974-10:2014+AMD1:2015 CSV | Arc welding equipment - Part 10: Electromagnetic compatibility (EMC)requirements |
| 2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
| IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
| EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
| IEC 60601-2-2:2017 | Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
| IEC 61308:2005 | High-frequency dielectric heating installations - Test methods for the determination of power output |
| EN 61307:2011 | Industrial microwave heating installations - Test methods for the determination of power output |
| IEC 62135-2:2015 | Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
| CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
| CISPR TR 16-4-4:2007 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services |
| EN 60974-10:2014/A1:2015 | ARC WELDING EQUIPMENT - PART 10: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS (IEC 60974-10:2014/A1:2015) |
| IEC 61307:2011 | Industrial microwave heating installations - Test methods for the determination of power output |
| IEC 60705:2010+AMD1:2014 CSV | Household microwave ovens - Methods for measuring performance |
| EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
Summarise
US$136.02
Excluding Tax where applicable