BS EN 1993-3-1:2006
Current
The latest, up-to-date edition.
Eurocode 3. Design of steel structures Towers, masts and chimneys
Hardcopy , PDF
English
01-31-2010
1 General
1.1 Scope
1.2 Normative references
1.3 Assumptions
1.4 Distinction between principles and
application rules
1.5 Terms and definitions
1.6 Symbols
1.7 Convention for cross section axes
2 Basis of design
2.1 Requirements
2.2 Principles of limit state design
2.3 Actions and environmental influences
2.4 Ultimate limit state verifications
2.5 Design assisted by testing
2.6 Durability
3 Materials
3.1 Structural steel
3.2 Connections
3.3 Guys and fittings
4 Durability
4.1 Allowance for corrosion
4.2 Guys
5 Structural analysis
5.1 Modelling for determining action effects
5.2 Modelling of connections
6 Ultimate limit states
6.1 General
6.2 Resistance of cross sections
6.3 Resistance of members
6.4 Connections
6.5 Special connections for masts
7 Serviceability limit states
7.1 Basis
7.2 Deflections and rotations
7.3 Vibrations
8 Design assisted by testing
9 Fatigue
9.1 General
9.2 Fatigue loading
9.3 Fatigue resistance
9.4 Safety assessment
9.5 Partial factors for fatigue
9.6 Fatigue of guys
Annex A [normative] - Reliability differentiation and
partial factors for actions
A.1 Reliability differentiation for masts and towers
A.2 Partial factors for actions
Annex B [informative] - Modelling of meteorological
actions
B.1 General
B.2 Wind force
B.3 Response of lattice towers
B.4 Response of guyed masts
Annex C [informative] - Ice loading and combinations
of ice with wind
C.1 General
C.2 Ice loading
C.3 Ice weight
C.4 Wind and ice
C.5 Asymmetric ice load
C.6 Combinations of ice and wind
Annex D [normative] - Guys, dampers, insulators,
ancillaries and other items
D.1 Guys
D.2 Dampers
D.3 Insulators
D.4 Ancillaries and other items
Annex E [informative] - Guy rupture
E.1 Introduction
E.2 Simplified analytical model
E.3 Conservative procedure
E.4 Analysis after a guy rupture
Annex F [informative] - Execution
F.1 General
F.2 Bolted connections
F.3 Welded connections
F.4 Tolerances
F.5 Prestretching of guys
Annex G [informative] - Buckling of components of
masts and towers
G.1 Buckling resistance of compression members
G.2 Effective slenderness factor k
Annex H [informative] - Buckling length and slenderness
of members
H.1 General
H.2 Leg members
H.3 Bracing members
H.4 Secondary bracing members
H.5 Shell structures
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.