Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 2629-2008

Current

Current

The latest, up-to-date edition.

Separable insulated connectors for power distribution systems above 1 kV (Reconfirmed 2019)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

15-08-2008

$149.01
Including GST where applicable

1 - AS 2629-2008 SEPARABLE INSULATED CONNECTORS FOR POWER DISTRIBUTION SYSTEMS ABOVE 1 KV
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 REFERENCED DOCUMENTS
6 - 1.3 SERVICE CONDITIONS
6 - 1.3.1 Normal service conditions
7 - 1.3.2 Special service conditions
8 - SECTION 2 DEFINITIONS
8 - 2.1 APPLICATION OF SECTION
8 - 2.2 GENERAL TERMS
8 - 2.2.1 Dead-break connector
8 - 2.2.2 Load-break connector
8 - 2.2.3 Operating interface
8 - 2.2.4 Separable insulated connector (hereinafter referred to as connector)
8 - 2.3 HARDWARE ITEMS
8 - 2.3.1 Bushing insert
8 - 2.3.2 Bushing well
8 - 2.3.3 Earthing (grounding) bushing
8 - 2.3.4 Earthing elbow
8 - 2.3.5 Earthing rod
8 - 2.3.6 Elbow
9 - 2.3.7 Feed-through device
9 - 2.3.8 Hold-down bail
9 - 2.3.9 Insulated parking bushing
9 - 2.3.10 Insulated cap
9 - 2.3.11 Integral bushing
9 - 2.3.12 Parking stand
9 - 2.3.13 Plug
9 - 2.3.14 Test point
9 - 2.4 ELECTRICAL CHARACTERISTICS
9 - 2.4.1 Partial discharge (corona) extinction voltage
9 - 2.4.2 Rated short-circuit making current
9 - 2.4.3 Rated lightning impulse withstand voltage
9 - 2.4.4 Rated normal current
9 - 2.4.5 Rated (short duration) power frequency withstand voltage
10 - 2.4.6 Rated short-time withstand current
10 - 2.4.7 Rated switching current
10 - 2.4.8 Rated voltage
15 - SECTION 3 RATINGS
15 - 3.1 VOLTAGE RATINGS
15 - 3.1.1 Rated voltage
15 - 3.1.2 Insulation level
15 - 3.1.3 Partial discharge extinction voltage
15 - 3.2 RATED FREQUENCY
15 - 3.3 CURRENT RATINGS
15 - 3.3.1 Normal current
15 - 3.3.2 Switching current (load-break connectors)
15 - 3.3.3 Short-time withstand current
16 - 3.3.4 Short-circuit making current (load-break connectors)
17 - SECTION 4 DESIGN, CONSTRUCTION AND MARKING
17 - 4.1 DESIGN
17 - 4.2 INTERCHANGEABILITY
17 - 4.3 OPERATING MEANS
17 - 4.4 SHIELDING
17 - 4.5 TEST POINTS
17 - 4.5.1 Requirements
17 - 4.5.2 Capacitance
17 - 4.6 HOLD-DOWN BAILS
18 - 4.7 MARKING
30 - SECTION 5 PERFORMANCE
30 - 5.1 BEHAVIOUR ON TEST AND IN SERVICE
30 - 5.1.1 Current-carrying performance
30 - 5.1.2 Switching current performance
30 - 5.1.3 Short-circuit making current performance
30 - 5.1.4 Operating forces and torques
30 - 5.2 OPERATING TEMPERATURE OF MATERIALS
31 - SECTION 6 CLASSIFICATION OF TESTS
31 - 6.1 TYPE TESTS
31 - 6.1.1 Purpose
31 - 6.1.2 Connectors tested
31 - 6.1.3 Test report
31 - 6.1.4 Repeat tests
31 - 6.1.5 Test records
31 - 6.2 ROUTINE TESTS
31 - 6.3 TESTS AT SITE
31 - 6.3.1 General
32 - 6.3.2 Power-frequency voltage tests
32 - 6.3.3 D.C. voltage tests
32 - 6.3.4 Other tests
34 - SECTION 7 DETAILS OF TYPE TESTS
34 - 7.1 DIELECTRIC TESTS
34 - 7.1.1 Purpose
34 - 7.1.2 Mounting preparation
34 - 7.1.3 Requirements
34 - 7.1.4 Power frequency voltage
34 - 7.1.5 Partial discharge
34 - 7.1.6 D.C. voltage
34 - 7.1.7 Impulse
35 - 7.2 SHORT-CIRCUIT CURRENT-CARRYING CAPABILITY TEST
35 - 7.2.1 Purpose
35 - 7.2.2 Mounting preparation
35 - 7.2.3 Requirements
35 - 7.3 SWITCHING CURRENT TESTS (Applicable to load-break connectors only)
35 - 7.3.1 Purpose
35 - 7.3.2 Mounting preparation
36 - 7.3.3 Requirements
36 - 7.3.4 Electrical circuit conditions
37 - 7.4 SHORT-CIRCUIT MAKING CURRENT TEST (Applicable to load-break connectors only)
37 - 7.4.1 Purpose
37 - 7.4.2 Mounting preparation
37 - 7.4.3 Requirements
37 - 7.5 CONNECTOR ELBOW DISTORTION TEST FOR OFF-AXIS FORCE (Applicable only to elbows of the non-bolted type).
37 - 7.5.1 Purpose
37 - 7.5.2 Preparation for test
40 - 7.5.3 Off-axis operating tests
40 - 7.5.4 Verification of results
40 - 7.6 CURRENT CYCLING TEST
40 - 7.6.1 Purpose
41 - 7.6.2 Preparation for test
41 - 7.6.3 Requirements
41 - 7.6.4 Verification of results
41 - 7.7 CABLE PULL-OUT TEST
41 - 7.7.1 Purpose
41 - 7.7.2 Requirements
42 - 7.8 OPERATING FORCE TEST
42 - 7.8.1 Purpose
42 - 7.8.2 Requirements
42 - 7.9 OPERATING EYE TEST
42 - 7.9.1 Purpose
42 - 7.9.2 Test method and requirements
42 - 7.10 TEST POINT CAP MECHANICAL TEST
42 - 7.10.1 Purpose
42 - 7.10.2 Removal force
42 - 7.10.3 Operating force withstand
43 - 7.11 TEST POINT ELECTRICAL TESTS
43 - 7.11.1 Purpose
43 - 7.11.2 Capacitance test
43 - 7.11.3 Voltage indication test
43 - 7.12 SHIELDING TEST
43 - 7.12.1 Purpose
43 - 7.12.2 Test procedure
43 - 7.13 ACCELERATED SEALING LIFE TEST
43 - 7.13.1 Purpose
43 - 7.13.2 Sequence
43 - 7.13.3 Thermal ageing test
44 - 7.13.4 Heating and immersion cycles
44 - 7.13.5 Verification of results

This Standard applies a method of connection and switching of transformers and other electrical equipment in distribution systems using special flexible cable connectors.

Committee
EL-007
DocumentType
Standard
ISBN
0 7337 8869 6
Pages
39
ProductNote
Reconfirmed 01/11/2019.
This standard has been reconfirmed in Australia in 2019 and remains current in New Zealand. Reconfirmation Notice 01/11/2019
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies requirements for load-break and dead-break separable insulated connectors and ancillary equipment for use on power distribution systems at alternating voltages above 1 kV.The Standard applies to separable insulated connectors rated at not more than 1250 A.NOTE: Load-break connectors are available only for the lower current ratings. The purchaser should obtain information from manufacturers on available current ratings.

Originated as AS 2629-1983.
Second edition 2008.

AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 60270-2001 High-voltage test techniques - Partial discharge measurements
AS/NZS 1429.1:2006 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV (Reconfirmed 2017)

$149.01
Including GST where applicable