AS/NZS 3947.4.1:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage switchgear and controlgear Contactors and motor-starters - Electromechanical contactors and motor-starters
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
12-10-2001
30-06-2017
Applies to a.c. and d.c. contactors and a.c. motor-starters whose main contacts are intended to be connected to circuits, the rated voltage of which does not exceed 1000 volt a.c. or 1500 volt d.c. Specifies requirements for contactors associated with overload or short-circuit protective devices, starters associated with short-circuit and integrated overload protective devices and contactors or starters combined with their own short-circuit protective devices. This Standard is identical to and reproduced from IEC 60947-4-1:2000.
| Committee |
EL-006
|
| DocumentType |
Standard
|
| ISBN |
0 7337 4045 6
|
| Pages |
81
|
| PublisherName |
Standards Australia
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes | |
| UnderRevision |
This part of IEC 60947 applies to the types of equipment listed in 1.1 and 1.2 whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.Starters and/or contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection (see 9.3.4) shall form part of the installation but not necessarily of the contactor or the starter.In this context, this standard gives requirements for: contactors associated with overload and/or short-circuit protective devices; starters associated with separate short-circuit protective devices and/or with separate short-circuit and integrated overload protective devices; contactors or starters combined, under specified conditions, with their own short-circuit protective devices. Such combinations, e.g. combination starters (see 3.2.7) or protected starters (see 3.2.8) are rated as units.Circuit-breakers and fuse-combination units used as short-circuit protective devices in combination starters and in protected starters shall comply with the requirements of IEC 60947-2 and IEC 60947-3, as the case may be.Equipment covered by this standard is as follows.
| Standards | Relationship |
| IEC 60947-4-1:2000 | Identical |
AS 3947.4.1 first published in part as AS C165-1961.
AS C63 first published 1965.
AS C364 first published 1967.
AS C381 first published 1967.
AS C63-1965 revised and redesignated AS 1029-1971.
AS C165-1961 revised and redesignated AS 1023.2-1972.
AS C364-1967 revised and redesignated in part as AS 1202.1-1972.
AS 1202-1972 redesignated AS 1202.1-1972.
Second edition AS 1029-1974.
AS C381-1967 revised and redesignated AS 1202.2-1976, AS 1202.3-1976 and AS 1202.4-1976.
Second edition AS 1202.1-1981.
AS 1029-1974 revised and redesignated in part as AS 1029.1-1982.
Second edition AS 1029.1-1985.
Second edition AS 1023.2-1989.
AS 1023.2-1989, AS 1029.1-1985, AS 1201.1-1981, AS 1202.2-1976, AS 1202.3-1976 and AS 1202.4-1976 revised, amalgamated and redesignated AS 3947.4.1-1995.
Second edition 2001.
A newer version of this standard is available.
View Current Edition