BS EN 445:2007
Current
The latest, up-to-date edition.
Grout for prestressing tendons. Test methods
Hardcopy , PDF
English
30-11-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 The testing of grout
4.1 General
4.1.1 Personnel
4.1.2 Test conditions
4.1.3 Test reports
4.2 Sieve test
4.2.1 Principle of test
4.2.2 Apparatus
4.2.3 Procedure
4.2.4 Reporting
4.3 Fluidity test
4.3.1 Cone method
4.3.2 Grout spread method
4.4 Inclined tube test
4.4.1 Principle of test
4.4.2 Test equipment and set-up
4.4.3 Test procedure
4.4.4 Reporting of results
4.5 Wick-induced test
4.5.1 Principle of test
4.5.2 Equipment
4.5.3 Procedure
4.5.4 Reporting of results
4.6 Compressive strength test
4.6.1 Principle of the test
4.6.2 Apparatus
4.6.3 Test procedure
4.7 Density test
4.7.1 Principle of test
4.7.2 Apparatus
4.7.3 Reporting of results
Bibliography
Covers test methods for grout as defined in EN 447.
| Committee |
B/525/2
|
| DevelopmentNote |
Supersedes 91/10645 DC. (09/2005) Supersedes 05/30139290 DC. (11/2007)
|
| DocumentType |
Standard
|
| Pages |
18
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This European Standard describes the test methods for grout specified in EN 447. Testing shall be performed in accordance with the test methods given in this standard (reference test methods). The test methods are applicable to grout for all types of structures including bridges and buildings.
| Standards | Relationship |
| EN 446:2007 | Identical |
| NF EN 445 : 2007 | Identical |
| EN 445:2007 | Identical |
| I.S. EN 445:2007 | Identical |
| NS EN 445 : 2ED 2007 | Identical |
| NEN EN 445 : 2007 | Identical |
| NBN EN 445 : 2007 | Identical |
| EN 447:2007 | Identical |
| UNE-EN 445:2009 | Identical |
| DIN EN 445:2008-01 | Identical |