Grout for prestressing tendons - Basic requirements
03-10-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Materials
4.1 Cement
4.2 Water
4.3 Admixtures
4.4 Additions
5 Batching and mixing of grout
6 Properties of grout
6.1 General
6.2 Sieve test
6.3 Fluidity
6.4 Bleeding
6.5 Volume change
6.6 Strength
6.7 Setting time
6.8 Density
7 Evaluation of conformity
7.1 Production control
7.2 Initial type testing
7.3 Audit testing
Bibliography
This European Standard covers the materials that may be used in the manufacture of cement grouts and the required properties and composition of the grout. It is applicable to grouting of tendons in all types of structures including bridges and buildings.