BS EN 61689:2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
Hardcopy , PDF
English
31-05-2013
18-01-2023
| Committee |
EPL/87
|
| DevelopmentNote |
Supersedes 93/203591 DC. (09/2005) Supersedes 04/30115966 DC. (12/2007) Supersedes 11/30230872 DC. (05/2013)
|
| DocumentType |
Standard
|
| Pages |
66
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
IEC 61689:2013 is applicable to ultrasonic equipment designed for physiotherapy containing an ultrasonic transducer generating continuous or quasi-continuous wave ultrasound in the frequency range 0,5 MHz to 5 MHz. This standard only relates to ultrasonic physiotherapy equipment employing a single plane non-focusing circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This standard specifies:
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods;
- characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods;
- guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment;
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods;
- and acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods. Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not covered by the scope of this standard. This third edition cancels and replaces the second edition published in 2007. It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- restriction introduced of 0,2 W/cm 2 effective intensity during hydrophone measurements for treatment heads with ka?20, to limit the likelihood of cavitation;
- change in the factor F ac, to determine the effective radiating area, from 1,354 to 1,333;
- and change to SI units for terms and definitions.
This publication is to be read in conjunction with IEC 60601-2-5:2009.
| Standards | Relationship |
| DIN EN 61689 : 2013 | Identical |
| NBN EN 61689 : 2013 | Identical |
| IEC 61689:2013 | Identical |
| NF EN 61689 : 2013 | Identical |
| EN 61689:2013 | Identical |
| IEC TR 63084:2017 | Identical |
| I.S. EN 61689:2013 | Identical |
| UNE-EN 61689:2013 | Equivalent |
| UNE-EN 61689:1999 | Identical |
A newer version of this standard is available.