Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CEI EN 50131-2-3 : 2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS

Available format(s)

Hardcopy , PDF

Language(s)

English - Italian

Published date

01-01-2009

Superseded date

10-07-2025

Superseded by

CEI EN 50131-2-3:2022-10

$326.98
Including GST where applicable

INTRODUCTION
1 Scope
2 Normative references
3 Definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Dimensions & requirements
        of the standardised test magnets
Annex B (normative) - General testing matrix
Annex C (informative) - Walk test diagrams
Annex D (informative) - Equipment for walk
        test velocity control
Annex E (informative) - Immunity to microwave
        signal interference by fluorescent lights
Annex F (informative) - Example list of small tools
Annex G (normative) - Test for resistance to
        re-orientation of adjustable mountings
Bibliography

Gives the security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5).

Committee
CT 79
DevelopmentNote
Classificazione CEI 79-57. Supersedes CEI CLC/TS 50131-2-3. (09/2009) An interpretation sheet 2015 exists for CEI EN 50131-2-3, See CEI EN 50131-2-3/IS1. (12/2015)
DocumentType
Standard
Pages
74
PublisherName
Comitato Elettrotecnico Italiano
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
EN 50131-2-3:2008 Identical

CEI 79-3 : 2012 ALARM SYSTEMS - PARTICULAR REQUIREMENTS FOR INTRUSION AND HOLD-UP INSTALLATIONS

IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
EN 50130-5:2011 Alarm systems - Part 5: Environmental test methods

$326.98