• Shopping Cart
    There are no items in your cart

ANSI C57.12.25 : 1990

Withdrawn

Withdrawn

TRANSFORMERS - PAD-MOUNTED, COMPARTMENTAL-TYPE, SELF-COOLED, SINGLE-PHASE DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS; HIGH VOLTAGE, 34 500 GRDY/19 920 VOLTS AND BELOW; LOW VOLTAGE, 240/120 VOLTS; 167 KVA AND SMALLER - REQUIREMENTS

Published date

01-01-1990

Withdrawn date

10-18-2023

Sorry this product is not available in your region.

1 Scope
2 Normative references
  2.1 General
3 Ratings
  3.1 Kilovolt-ampere ratings
  3.2 Voltage ratings and tap ratings
4 Basic lightning Impulse insulation levels and dielectric
  test levels
5 Tests
  5.1 General
  5.2 Dielectric tests
6 Construction
  6.1 General
  6.2 Connectors and terminals
  6.3 High-voltage and low-voltage compartment
  6.4 Instruction nameplate
  6.5 Oil preservation
  6.6 Tanks
  6.7 Components for looped primary cable systems
7 Storage and Installation
  7.1 Storage
  7.2 Installation
8 Other requirements that may be specified for some applications

Describes certain electrical, dimensional, and mechanical characteristics, and takes into consideration certain safety features of single-phase, 60-Hz, mineral-oil-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers with separable insulated high-voltage connectors.

DevelopmentNote
Supersedes IEEE DRAFT C57.12.25. (08/2004)
DocumentType
Standard
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn

IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
IEEE C57.12.30-2010 IEEE Standard for Pole-Mounted Equipment--Enclosure Integrity for Coastal Environments
ANSI C57.12.27 : 1982 LIQUID-FILLED DISTRIBUTION TRANSFORMERS USED IN PAD-MOUNTED INSTALLATIONS INCLUDING UNIT SUBSTATIONS CONFORMANCE STANDARD FOR,
IEEE 3001.5-2013 IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems
IEEE DRAFT C57.12.90 : D5.1 98 DRAFT STANDARD TEST CODE FOR LIQUID-IMMERSED DISTRIBUTION, POWER, AND REGULATING TRANSFORMERS
IEEE C57.12.31-2010 IEEE Standard for Pole-Mounted Equipment--Enclosure Integrity
IEEE 1388-2000 IEEE Standard for the Electronic Reporting of Transformer Test Data

IEEE C57.12.20-2011 TRANSFORMERS - STANDARD FOR OVERHEAD TYPE DISTRIBUTION TRANSFORMERS, 500 KVA AND SMALLER: HIGH VOLTAGE, 34500 VOLTS AND BELOW: LOW VOLTAGE, 7970/13800Y VOLTS AND BELOW
IEEE 386-2016 REDLINE IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
ANSI C57.12.28 : 2014 PAD-MOUNTED EQUIPMENT - ENCLOSURE INTEGRITY
IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers

Sorry this product is not available in your region.