ASTM C 1150 : 1996
Withdrawn
Standard Test Method for the Break-Off Number of Concrete (Withdrawn 2002)
English
05-10-1996
01-10-2002
CONTAINED IN VOL 04.02, 2001 By measuring the force required to cause failure of a pre-cast or drilled core specimen loaded as a cantilever this test method covers determination of the break-off number of hardened concrete in test specimens or structures.
| Committee |
C 09
|
| DocumentType |
Test Method
|
| Pages |
4
|
| PublisherName |
American Society for Testing and Materials
|
| Status |
Withdrawn
|
1.1 This test method covers determination of the break-off number of hardened concrete in test specimens or structures, by measuring the force required to cause failure of a pre-cast or drilled core specimen loaded as a cantilever.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
| ACI 325.11R : 2001 | ACCELERATED TECHNIQUES FOR CONCRETE PAVING |
| ACI 228.1R : 2003 | IN-PLACE METHODS TO ESTIMATE CONCRETE STRENGTH |
| ASTM C 823 : 2000 | Standard Practice for Examination and Sampling of Hardened Concrete in Constructions |
| ASTM C 670 : 2015 : REDLINE | Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials |