BS EN 61241-14:2004

Superseded

Superseded

View Superseded by

Electrical apparatus for use in the presence of combustible dust Selection and installation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

11-26-2004

Superseded date

04-30-2012

Superseded by

BS EN 60079-14:2014

US$391.00
Excluding Tax where applicable
Summarise this standard

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements for all types of protection
   4.1 Access for inspection
   4.2 Associated equipment located in non-hazardous areas
   4.3 Segregation
   4.4 Electrical rating
   4.5 Protection from mechanical damage and environmental injury
   4.6 Documentation
   4.7 Qualifications of personnel
   4.8 Additional considerations
   4.9 Prevention of explosion
5 Area classification
6 Selection of electrical apparatus
   6.1 Permitted apparatus
   6.2 Selection according to dust characteristics and zones
   6.3 Selection according to temperature
   6.4 Selection of apparatus
7 Protection from dangerous (incendive) sparking
   7.1 Danger from live parts
   7.2 Danger from exposed and extraneous conductive parts
   7.3 Potential equalization
   7.4 Static electricity
   7.5 Electromagnetic radiation
   7.6 Lightning protection
   7.7 Cathodically protected metallic parts
8 Electrical protection
   8.1 General
   8.2 Location of protection and control equipment
   8.3 Resetting of short-circuit and earth-fault protection
        devices
   8.4 Protection of rotating electrical machinery
   8.5 Loss of supply phase
   8.6 Transformer protection
9 Emergency switch-off and electrical isolation
   9.1 Emergency switch-off
   9.2 Electrical isolation
10 Wiring systems
   10.1 General
   10.2 Entries for cable and conduit
   10.3 Accessories
   10.4 Course of wiring
   10.5 Barriers
   10.6 Flexible connection
   10.7 Cable entries
   10.8 Unauthorized methods
   10.9 Telecommunications circuits
   10.10 Unused openings
11 Plugs and socket outlets
   11.1 General
   11.2 Mounting
   11.3 Location
12 Additional requirements for type of protection "Ex tD"
   12.1 Practices A and B
   12.2 Practice A
   12.3 Practice B
   12.4 Motors supplied at varying frequency and voltages
13 Additional requirements for type of protection "pD"
   13.1 Sources of protective gas
   13.2 Automatic switch-off
   13.3 Alarm
   13.4 Common source of protective gas
   13.5 Switching on electrical supply
   13.6 Motors supplied at varying frequency and voltages
14 Additional requirements for type of protection "iD"
15 Additional requirements for type of protection "mD"
16 Inspection of installation
   16.1 General
   16.2 Testing
Annex A (informative) Examples of dust layers of excessive
        thickness
Annex B (normative) Frictional sparking risks with light metals
        and their alloys
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Bibliography

Describes general requirements, additional to those required for basic electrical safety, for the selection of electrical apparatus and instruments and associated equipment, and for the installation of electrical apparatus to ensure safe use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard.

Committee
EXL/31
DevelopmentNote
Supersedes 02/205211 DC. (12/2004) Together with BS EN 61241-17, it supersedes BS EN 50281-1-2. (08/2005) Together with BS EN 61241-0, BS EN 61241-1 and BS EN 61241-17, it supersedes BS 6467-1(1985) and BS 6467-2(1988). (01/2007)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Specifies general requirements, additional to those required for basic electrical safety, for the selection of electrical apparatus and instruments and associated equipment, and for the installation of electrical apparatus to ensure safe use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures.

Standards Relationship
NF EN 61241-14 : 2004 Identical
DIN EN 61241-14 : 2005 Identical
I.S. EN 61241-14:2004 Identical
IEC 61241-14:2004 Identical
NBN EN 61241-14 : 2005 Identical
EN 61241-14:2004 Identical
IEC 60331-11:1999/AMD1:2009 Identical
UNE-EN 61241-14:2006 Identical

⚠

A newer version of this standard is available.