BS EN 60079-14:2014
Superseded
View Superseded by
Explosive atmospheres Electrical installations design, selection and erection
Hardcopy , PDF
English
04-30-2016
08-06-2026
| Committee |
EXL/31/3
|
| DevelopmentNote |
Supersedes BS 4137(1967), BS 5345-1(1989), BS 5345-3(1979), BS 5345-4(1977), BS 5345-5(1983), BS 5345-6(1978), BS 5345-7(1979) and BS 5345-8(1980) Supersedes 00/241830 DC (09/2003) Supersedes 91/25141 DC. (03/2007) Supersedes 05/30138005 DC. (01/2009) Supersedes BS EN 61241-14. (04/2012) Supersedes 12/30269297 DC. (07/2014)
|
| DocumentType |
Standard
|
| ISBN |
9780539035902
|
| Pages |
146
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
|
This part of the IEC60079 series contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associated with, explosive atmospheres. Where the equipment is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional protection requirements may be necessary. The requirements of this standard apply only to the use of equipment under standard atmospheric conditions as defined in IEC60079‑0 . For other conditions, additional precautions may be necessary, and the equipment should be certified for these other conditions. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. NOTE1 The standard atmospheric conditions defined in IEC60079‑0 relate to the explosion characteristics of the atmosphere and not the operating range of the equipment i.e. Temperature: −20°C to 60°C; Pressure: 80kPa (0,8bar) to 110kPa (1,1bar); and air with normal oxygen content, typically 21% v/v. These requirements are in addition to the requirements for installations in non-hazardous areas. NOTE2 For voltages up to 1000V a.c. or 1500V d.c. requirements of this standard are based on installation requirements in the IEC60364 series, but other relevant national requirements can apply. This standard applies to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary. This standard does not apply to electrical installations in mines susceptible to firedamp; NOTE3 This standard can apply to electrical installations in mines where explosive gas atmospheres other than firedamp can be formed and to electrical installations in the surface installation of mines. inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing); rooms used for medical purposes; electrical installations in areas where the hazard is due to flammable mist. NOTE4 Additional guidance on the requirements for hazards due to hybrid mixtures of dust or flyings and flammable gas or vapour is provided in AnnexM. No account is taken in this Standard of the toxic risks that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower explosive limit. In locations where personnel may be exposed to potentially toxic concentrations of flammable material, appropriate precautions should be taken. Such precautions are outside the scope of this Standard.
| Standards | Relationship |
| NBN EN 60079-14 : 2014 COR 2016 | Identical |
| I.S. EN 60079-14:2014 | Identical |
| IEC 60079-14:2013 | Identical |
| NF EN 60079-14 : 2014 | Identical |
| IEC 60079-14:2013/COR1:2016 | Identical |
| EN 60079-14:2014 | Equivalent |
| EN 60079-14:2014/AC:2016 | Identical |
| DIN EN 60079-14:2014-10 | Equivalent |
| UNE-EN 60079-14:2016 | Identical |
A newer version of this standard is available.
View Current Edition