BS EN 62271-107:2012
Superseded
View Superseded by
High-voltage switchgear and controlgear Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
Hardcopy , PDF
English
09-30-2012
07-22-2019
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide for the selection of fused circuit-switchers
9 Information to be given with enquiries, tenders
and orders
10 Rules for transport, storage, installation,
operation and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (informative) - Applicability of the rated
take-over current test duty
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Applicable to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses.
| Committee |
PEL/17
|
| DevelopmentNote |
Supersedes 03/100521 DC. (04/2006) Supersedes 09/30213777 DC. (09/2012)
|
| DocumentType |
Standard
|
| Pages |
52
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
Subclause 1.1 of IEC 62271-1:2007 is not applicable, and is replaced as follows.
This part of IEC 62271 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of:
breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current;
making, at the rated voltage, circuits to which the rated short-circuit breaking current applies.
They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits.
Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher.
NOTE 1 In this standard the term \'fuse\' is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity.
This standard applies to fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. Comparison with other existing switching devices is provided in Clause 8.
NOTE 2 Other circuit-switchers exist; see reference [1]1.
Devices that require a dependent manual operation are not covered by this standard.
Fuses are covered by IEC 60282-1.
Earthing switches forming an integral part of a circuit-switcher are covered by IEC 62271-102.
Installation in enclosure, if any, is covered either by IEC 62271-200 or by IEC 62271-201.
| Standards | Relationship |
| IEC 62271-107:2012 | Identical |
| NF EN 62271-107 : 2013 | Identical |
| EN 62271-107:2012 | Identical |
| DIN EN 62271-107 : 2013-03 | Identical |
| NBN EN 62271-107 : 2012 | Identical |
| I.S. EN 62271-107:2012 | Identical |
| UNE-EN 62271-107:2012 | Identical |
A newer version of this standard is available.
View Current Edition