EN 62271-107:2012
Superseded
View Superseded by
High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
08-03-2012
07-18-2019
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide for the selection of fused circuit-switchers
9 Information to be given with enquiries, tenders
and orders
10 Rules for transport, storage, installation, operation
and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (informative) - Applicability of the rated
take-over current test duty
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Bibliography
IEC 62271-107:2012 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of: - breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current; - making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. This second edition cancels and replaces the first edition, published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. - the reference to IEC 60694 has been changed to IEC 62271-1; - the new clauses and subclauses from IEC 62271-1 have been added and where necessary new wording has been provided; - the normative references have been updated: IEC 60265-1 to IEC 62271-103, IEC 60787 to IEC/TR 60787, IEC 60466 to IEC 62271-201, and IEC/TR 60787 was moved to the bibliography; - the figures and tables have been placed in the document where they are first cited; - the numbering of figures and tables has been changed to obtain the correct order; - the definition of NSDD was deleted. This definition is included in IEC 62271-1; - the acceptance criteria have been aligned with 6.101.4 of IEC 62271-103:2011; - the various provisions expressed about 'extension of the validity of type tests' have been grouped under 6.103: some of the rules were duplicated in Clauses 6 and 8, and it seems better fitted to deal within each type test sub-clause only with the type test to be performed. Conditions have not been changed, but the wording is clearer; - new numbering of subclauses in Clauses 8 and 9 to avoid conflict with clauses from IEC 62271-1.
| Committee |
CLC/TC 17AC
|
| DevelopmentNote |
To be read in conjunction with EN 60694. (03/2006)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| VDE 0671-107 : 2013-03 | Identical |
| IEC 62271-107:2012 | Identical |
| BS EN 62271-107:2012 | Identical |
| CEI EN 62271-107 : 2013 | Identical |
| I.S. EN 62271-107:2012 | Identical |
| NF EN 62271-107 : 2013 | Identical |
| PN EN 62271-107 : 2013 | Identical |
| NEN EN IEC 62271-107 : 2012 | Identical |
| DIN EN 62271-107 : 2013-03 | Identical |
| NBN EN 62271-107 : 2012 | Identical |
| UNE-EN 62271-107:2012 | Identical |