CEN/TR 14383-8:2009
Current
The latest, up-to-date edition.
Prevention of crime - Urban planning and building design - Part 8: Protection of buildings and sites against criminal attacks with vehicles
09-30-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Protection against vehicles as tools of crime
5 Information and technical data
6 Protection specifications
7 Professional arrangement of the protective elements
Annex A (informative) Kinetic energy released when
ramming with vehicles, static test loads
Annex B (informative) Protective Elements
Bibliography
The purpose of this document is to describe the consequences and risks of the criminal use of motor vehicles against buildings or sites in order to better assess the threats and to establish a security analysis:a)identification of possible attack methods,b)recommendation of technical elements in the field of protection,c)description of a set of physical protective measures to reinforce the security of public and private buildings,d)recommendation of organizational measures.This document contains information for the professional implementation and application of preventive measures against the unauthorised access of vehicles into buildings or areas. It is necessary to achieve one of the four following protection levels:a)Traffic controlRegulating the use of the different spaces where vehicles occur: traffic lanes, car parks and parking areas, delivery places, pedestrian areas, access routes, etc. The delinquent uses his own vehicle and wants to avoid any damage on it.b)Protection against criminal attacks with vehiclesProtection against burglary, robbery, vandalism, etc. The delinquent uses stolen vehicles to commit criminal acts. He accepts the destruction of the vehicle but wants to preserve his integrity.c)Protection against urban violence and heavy vandalismProtection against ramming and burning cars used against private and public buildings and police enforcement or intervention forces. The delinquent uses any available vehicles. He shows no consideration for the life of other persons. He fights against institutions, authorities and their representatives and wants to destroy the social network of an area.d)Mitigation of the effect of explosives in combination with vehiclesMitigation of the effect of gas trucks, car bombs, etc. Security requirements on doors, windows, façades and their accessories are defined by CEN in normative documents.
Committee |
CEN/TC 325
|
DocumentType |
Technical Report
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NEN NPR CEN/TR 14383-8 : 2009 | Identical |
UNE-CEN/TR 14383-8:2011 IN | Identical |
FD CEN/TR 14383-8 : 2010 FD | Identical |
SIS-CEN/TR 14383-8:2009 | Identical |
S.R. CEN TR 14383-8:2009 | Identical |
CEI UNI EN 50518-1 : 2015 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
CEN/TR 16705 : 2014 | PERIMETER PROTECTION - PERFORMANCE CLASSIFICATION METHODOLOGY |
UNI CEI EN 50518-1 : 2014 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
EN 50518-1:2013 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
PD CEN/TR 16705:2014 | Perimeter protection. Performance classification methodology |
UNE-EN 50518-1:2014 | Monitoring and alarm receiving centre - Part 1: Location and construction requirements |
BS EN 50518-1:2013 | Monitoring and alarm receiving centre Location and construction requirements |
PREN 50518 : DRAFT 2016 | MONITORING AND ALARM RECEIVING CENTRE |
S.R. CEN/TR 16705:2014 | PERIMETER PROTECTION - PERFORMANCE CLASSIFICATION METHODOLOGY |
16/30299842 DC : 0 | BS EN 50518 - MONITORING AND ALARM RECEIVING CENTRE |
I.S. EN 50518-1:2013 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
EN 1906:2012 | Building hardware - Lever handles and knob furniture - Requirements and test methods |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
EN 13123-2:2004 | Windows, doors, and shutters - Explosion resistance - Requirements and classification - Part 2: Range test |
CEN/TS 14383-3 : 2005 | PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS |
EN 1303:2015 | Building hardware - Cylinders for locks - Requirements and test methods |
EN 1143-1:2012 | Secure storage units - Requirements, classification and methods of test for resistance to burglary - Part 1: Safes, ATM safes, strongroom doors and strongrooms |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN 10223-6:2012 | Steel wire and wire products for fencing and netting - Part 6: Steel wire chain link fencing |
EN 81-1:1998+A3:2009 | Safety rules for the construction and installation of lifts - Part 1: Electric lifts |
ENV 14383-2 : DRAFT 2003 | PREVENTION OF CRIME - URBAN PLANNING AND DESIGN - PART 2: URBAN PLANNING |
EN 14383-1:2006 | Prevention of crime - Urban planning and building design - Part 1: Definition of specific terms |
EN 12839:2012 | Precast concrete products - Elements for fences |
EN 12209:2016 | Building hardware - Mechanically operated locks and locking plates - Requirements and test methods |
EN 1176-1:2017 | Playground equipment and surfacing - Part 1: General safety requirements and test methods |
EN 13123-1:2001 | Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 1: Shock tube |
IEC 60598-2-3:2002+AMD1:2011 CSV | Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting |
CEN/TS 14383-4 : 2006 | PREVENTION OF CRIME - URBAN PLANNING AND DESIGN - PART 4: SHOPS AND OFFICES |
PREN 13637 : DRAFT 2014 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
ENV 1627:1999 | Windows, doors, shutters - Burglar resistance - Requirements and classification |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 1522:1998 | Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification |
EN 60598-2-3:2003/A1:2011 | LUMINAIRES - PART 2-3: PARTICULAR REQUIREMENTS - LUMINAIRES FOR ROAD AND STREET LIGHTING (IEC 60598-2-3:2002/A1:2011) |
EN 50132-7:2012 | Alarm systems - CCTV surveillance systems for use in security applications - Part 7: Application guidelines |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 50133-1 : 1996 AMD 1 2002 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.