EN ISO 11137-2:2015
Current
Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2:2013)
06-10-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, and abbreviated terms
4 Definition and maintenance of product families for dose
setting, dose substantiation, and sterilization
dose auditing
5 Selection and testing of product for establishing the
sterilization dose
6 Methods of dose establishment
7 Method 1: dose setting using bioburden information
8 Method 2: Dose setting using fraction positive information
from incremental dosing to determine an extrapolation factor
9 Method VD[max] - Substantiation of 25 kGy or 15 kGy
as the sterilization dose
10 Sterilization dose audit
11 Worked examples
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of
EU Directive 90/385/EEC on active implantable
medical devices
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements of
EU Directive 93/42/EEC on medical devices
Annex ZC (informative) - Relationship between this European
Standard and the Essential Requirements of
EU Directive 98/79/EC on in vitro diagnostic
medical devices
Bibliography
ISO 11137-2:2013 specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the sterilization dose to achieve a sterility assurance level, SAL, of 10−6. ISO 11137-2:2013 also specifies methods of sterilization dose audit used to demonstrate the continued effectiveness of the sterilization dose.ISO 11137-2:2013 defines product families for sterilization dose establishment and sterilization dose audit.
| Committee |
CEN/TC 204
|
| DevelopmentNote |
Supersedes EN 552. (07/2006) Supersedes PREN ISO 11137-2. (04/2012)
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| DS EN ISO 11137-2 : 2015 | Identical |
| ISO 11137-2:2013 | Identical |
| NF EN ISO 11137-2 : 2015 | Identical |
| NBN EN ISO 11137-2 : 2015 | Identical |
| NEN EN ISO 11137-2 : 2015 | Identical |
| NS EN ISO 11137-2 : 2015 | Identical |
| I.S. EN ISO 11137-2:2015 | Identical |
| PN EN ISO 11137-2 : 2015 | Identical |
| SS-EN ISO 11137-2:2015 | Identical |
| BS EN ISO 11137-2:2015 | Identical |
| ÖNORM EN ISO 11137-2:2023 10 01 | Identical |
| DIN EN ISO 11137-2:2015-11 | Identical |
| UNE-EN ISO 11137-2:2015 | Identical |