• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

IEC 61330:1995

Superseded

Superseded

View Superseded by

High-voltage/low voltage prefabricated substations

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

12-05-1995

Superseded date

06-13-2006

Superseded by

IEC 62271-202:2014

US$421.00
Excluding Tax where applicable
Summarise this standard

FOREWORD
INTRODUCTION
1 General
      1.1 Scope
      1.2 Normative references
      1.3 Definitions
2 Service conditions
      2.1 Normal service conditions
      2.2 Special service conditions
3 Requirements for components
4 Ratings
      4.1 Rated voltages
      4.2 Rated insulation levels
      4.3 Rated frequency and number of phases
      4.4 Rated normal currents and temperature rise
      4.5 Rated short-time withstand currents
      4.6 Rated peak withstand currents
      4.7 Rated duration of short circuit
      4.8 Rated supply voltage of operating devices and
             auxiliary circuits
      4.9 Rated supply frequency of operating devices and
             auxiliary circuits
      4.10 Rated maximum power of the prefabricated
             substation
      4.11 Rated class of enclosure
5 Designation and construction
      5.1 Earthing
      5.2 Auxiliary equipment
      5.3 Nameplate
      5.4 Degree of protection and internal fault
      5.5 Enclosure
      5.6 Sound emission
6 Type tests
      6.1 Dielectric tests
      6.2 Temperature-rise tests
      6.3 Short-time and peak withstand current tests on
             earthing circuits
      6.4 Functional tests
      6.5 Verification of the degree of protection
      6.6 Mechanical tests
7 Routine tests
      7.1 Voltage withstand tests on auxiliary circuits
      7.2 Functional tests
      7.3 Verification of correct wiring
      7.4 Tests after assembly on site
8 Guide to the selection of prefabricated substations
      for service
9 Information to be given with enquiries, tenders and
      orders
      9.1 Information with enquiries and orders
      9.2 Information with tenders
10 Rules for transport, erection, operation and
      maintenance
      10.1 Conditions during transport, storage and
             erection
      10.2 Erection
      10.3 Operation
      10.4 Maintenance
Annex A - Method for testing the prefabricated substation
          under conditions of arcing due to an internal fault
Annex B - Test to verify the sound level of a prefabricated
          substation
Annex C - Mechanical impact test
Annex D - Rating of transformers in an enclosure

Specifies the service conditions, rated characteristics, general structural requirements and test method of prefabricated substations, which are cable connected, for alternating current of primary rated voltages above 1 kV and up to and including 52 kV1, and for a transformer of maximum power 1 600 kVA, for service frequencies up to and including 60 Hz.

DevelopmentNote
Also numbered as BS EN 61330 (11/2005)
DocumentType
Standard
Pages
91
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
NF EN 61330 : 1996 Identical
NEN 11330 : 1996 Identical
I.S. EN 61330:1999 Identical
AS 61330-2005 Identical
VDE 0670-611 : 1997 Identical
DIN EN 61330 : 1997 Identical
BIS IS 14786 : 2000(R2015) Identical
CEI EN 61330 : 1ED 1997 Identical
EN 61330:1996 Identical
UNE-EN 61330:1997 Identical

⚠

A newer version of this standard is available.

View Current Edition
US$421.00
Excluding Tax where applicable