IEEE 1415 : 2006
Withdrawn
INDUCTION MACHINERY MAINTENANCE TESTING AND FAILURE ANALYSIS
01-01-2006
09-12-2023
1 Overview
1.1 Scope
1.2 Purpose
2 Normative references
3 Definitions
4 Maintenance inspections and tests
4.1 Safety for inspections and tests
4.2 Maintenance inspections
4.3 Maintenance tests
5 Determination and investigation of failure occurrence
5.1 Following a suspected failure
5.2 Investigation flow chart
5.3 Data collection
6 Failure analysis
6.1 Common symptoms and causes
6.2 Stator failures
6.3 Rotor failure modes
6.4 Shaft failures
6.5 Lubrication and bearing failure modes
6.6 Structures
6.7 Ventilation
6.8 Accessories
Annex A (informative) Bibliography
Annex B (informative) Suggested checklists
Annex C (informative) Failure investigation test methods
Presents maintenance testing and failure analysis guidance for form-wound, squirrel cage, induction machinery rated up to 15 kV.
| DevelopmentNote |
Supersedes IEEE DRAFT 1415. (10/2007)
|
| DocumentType |
Standard
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| NEMA MG 1 : 2016 | MOTORS AND GENERATORS |
| NEMA MG 2:2014 | Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators |
| NEMA MG 10:2017 | Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors |
| IEEE 841-2009 | IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp) |
| NFPA 70B : 2016 | RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE |
| IEEE 389-1996 | IEEE Recommended Practice for Testing Electronics Transformers and Inductors |
| IEEE 95-2002 | IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage |
| ASTM E 1444 : 2005 | Standard Practice for Magnetic Particle Testing |
| IEEE 1434-2014 | IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery |
| ANSI/NEMA C50.41 : 2012 | POLYPHASE INDUCTION MOTORS FOR POWER GENERATION STATIONS |
| API STD 541 : 2014 | FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER |
| IEEE 1068-2015 | IEEE Standard for the Repair and Rewinding of AC Electric Motors in the Petroleum, Chemical, and Process Industries |
| IEEE 43-2013 REDLINE | IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery |
| IEEE 112-2004 | IEEE Standard Test Procedure for Polyphase Induction Motors and Generators |
| IEEE 286-2000 | IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation |