IEEE 43-2013 REDLINE
Withdrawn
IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery
English
03-06-2014
03-21-2024
1 Overview
2 Normative references
3 Definitions
4 Safety considerations
5 Insulation resistance-general theory
6 Factors affecting insulation resistance
7 Conditions for measuring insulation resistance
8 Winding connections for insulation
resistance tests
9 Methods of measuring insulation resistance
10 Precautions
11 Interpretation of insulation resistance and
polarization index test results
12 Recommended minimum value of polarization
index and insulation resistance
Annex A (informative) - Variants in polarization index
Annex B (informative) - Direct versus alternating
voltage testing
Annex C (informative) - Monitoring charge and
discharge currents
Annex D (informative) - Insulation resistance profiling
(IRP)
Annex E (informative) - Bibliography
This document describes a recommended procedure for measuring insulation resistance of armature and field windings in rotating machines rated 750 W or greater.
| Committee |
Electric Machinery
|
| DevelopmentNote |
Supersedes IEEE DRAFT 43. (04/2001)
|
| DocumentType |
Standard
|
| ISBN |
978-0-7381-8937-6
|
| Pages |
75
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| Supersedes |
| IEEE 902-1998 | IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book) (Color Book® Series) |
| IEEE 1095-2012 REDLINE | IEEE Guide for the Installation of Vertical Generators and Generator/Motors for Hydroelectric Applications |
| IEEE 1068-2015 | IEEE Standard for the Repair and Rewinding of AC Electric Motors in the Petroleum, Chemical, and Process Industries |
| IEEE 3004.8-2016 | IEEE Recommended Practice for Motor Protection in Industrial and Commercial Power Systems |
| IEEE 1665 : 2009 | GUIDE FOR THE REWIND OF SYNCHRONOUS GENERATORS, 50 HZ AND 60 HZ, RATED 1 MVA AND ABOVE |
| NFPA 70B : 2016 | RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE |
| IEEE DRAFT 1147 : D8 2005 | GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS |
| ASME AG-1 : 2019 | CODE ON NUCLEAR AIR AND GAS TREATMENT |
| ASME AG 1 : 2012 | CODE ON NUCLEAR AIR AND GAS TREATMENT |
| IEEE 115-2019 | IEEE Guide for Test Procedures for Synchronous Machines Including Acceptance and Performance Testing and Parameter Determination for Dynamic Analysis |
| IEEE C62.21 : 2003 | GUIDE FOR THE APPLICATION OF SURGE VOLTAGE PROTECTIVE EQUIPMENT ON AC ROTATING MACHINERY 1000 V AND GREATER |
| IEEE DRAFT 1248 : D7 97 | DRAFT GUIDE FOR THE COMMISSIONING OF ELECTRICAL SYSTEMS IN HYDROELECTRIC POWER PLANTS |
| IEEE 334 : 2007 | QUALIFYING CONTINUOUS DUTY CLASS 1E MOTORS FOR NUCLEAR POWER GENERATING STATIONS |
| IEEE DRAFT C50.12 : D10 2004 | SALIENT-POLE 50 AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE |
| S.R. CLC/TS 60034-27:2011 | ROTATING ELECTRICAL MACHINES - PART 27: OFF-LINE PARTIAL DISCHARGE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES |
| NETA ATS : 2017 | ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS |
| IEEE DRAFT 434 : D10 2006 | FUNCTIONAL EVALUATION OF INSULATION SYSTEMS FOR AC ELECTRIC MACHINES RATED 2300 V AND ABOVE |
| NEMA ICS 16:2001 | Motion/Position Control Motors, Controls and Feedback Devices |
| NEMA MG 7 : 93 REV 1 96 | MOTION/POSITION CONTROL MOTORS AND CONTROLS |
| IEEE 3006.3-2017 | IEEE Recommended Practice for Determining the Impact of Preventative Maintenance on the Reliability of Industrial and Commercial Power Systems |
| IEEE 1290-2015 | IEEE Guide for Motor-Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power-Generating Stations |
| IEEE 95-2002 | IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage |
| API STD 541 : 2014 | FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER |
| IEEE C50.13 : 2014 | CYLINDRICAL-ROTOR 50 HZ AND 60 HZ, SYNCHRONOUS GENERATORS RATED 10 MVA AND ABOVE |
| IEEE DRAFT 67 : D5 2005 | GUIDE FOR THE OPERATION AND MAINTENANCE OF TURBINE GENERATORS |
| IEEE 434-2006 | IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above |
| API 546 : 2008 | BRUSHLESS SYNCHRONOUS MACHINES - 500 KVA AND LARGER |
| IEEE 252 : 1995 | TEST PROCEDURE FOR POLYPHASE INDUCTION MOTORS HAVING LIQUID IN THE MAGNETIC GAP |
| IEEE 1205-2014 | IEEE Guide for Assessing, Monitoring, and Mitigating Aging Effects on Electrical Equipment Used in Nuclear Power Generating Stations and Other Nuclear Facilities |
| IEEE 115-2009 REDLINE | IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis |
| IEC 60034-27-4:2018 | Rotating electrical machines - Part 27-4: Measurement of insulation resistance and polarization index of winding insulation of rotating electrical machines |
| IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
| IEC 60034-27-1:2017 | Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation |
| IEEE 1147-2005 | IEEE Guide for the Rehabilitation of Hydroelectric Power Plants |
| CLC/TS 60034-27:2011 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
| 05/30128254 DC : DRAFT JAN 2005 | IEC 60034-27 - ROTATING ELECTRICAL MACHINES - PART 27: PARTIAL DISCHARGE OFF-LINE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING MACHINERY |
| DD CLC/TS 60034-27:2011 | Rotating electrical machines Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
| IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
| (INACTIVE RECORD)IEEE C50.12 : 2005 | SALIENT-POLE 50 HZ AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE |
| IEEE 2030.2-2015 | IEEE Guide for the Interoperability of Energy Storage Systems Integrated with the Electric Power Infrastructure |
| IEEE 1415 : 2006 | INDUCTION MACHINERY MAINTENANCE TESTING AND FAILURE ANALYSIS |
| IEEE 112-2004 | IEEE Standard Test Procedure for Polyphase Induction Motors and Generators |
| IEEE DRAFT 1068 : D3 JUN 96 | RECOMMENDED PRACTICE FOR THE REPAIR AND REWINDING OF MOTORS FOR THE PETROLEUM AND CHEMICAL INDUSTRY |
| IEEE 841.1-2023 | IEEE Standard for Process Industry--International Energy Efficiency Class 3 (IE3) Premium-Efficiency, Severe Duty, Totally Enclosed Frame Surface Cooled Squirrel Cage Induction Motors--0.75 kW to 370 kW (1 hp to 500 hp) |
| IEEE C50.13-2014 | IEEE Standard for Cylindrical-Rotor 50 Hz and 60 Hz Synchronous Generators Rated 10 MVA and Above |
| IEEE 841-2021 | IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Squirrel Cage Induction Motors from 0.75 kW to 370 kW (1 hp to 500 hp) |
| IEEE 1812-2014 | IEEE Trial-Use Guide for Testing Permanent Magnet Machines |
| IEEE 252-2022 | IEEE Standard Test Procedure for Polyphase Induction Motors Having Liquid in the Magnetic Gap |
| NEMA MG 10012:2023 | Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators |
| IEEE 56-2016 | IEEE Guide for Insulation Maintenance of Electric Machines |
| IEEE 1017.4-2023 | IEEE Recommended Practice for Testing and Rating of Electrical Submersible Pump Motors |
| IEEE 112-2017 | IEEE Standard Test Procedure for Polyphase Induction Motors and Generators |
| IEEE 1812-2023 | IEEE Guide for Testing Permanent Magnet Machines |
| IEEE 1-2000 | IEEE Recommended Practice - General Principles for Temperature Limits in the Rating of Electrical Equipment and for the Evaluation of Electrical Insulation |
| NEMA MG 1 : 2016 | MOTORS AND GENERATORS |
| IEEE 67-2005 | IEEE Guide for Operation and Maintenance of Turbine Generators |
| IEEE 62.2-2004 | IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Electrical Machinery |
| IEEE 56-1977 | IEEE Guide for Insulation Maintenance of Large Alternating-Current Rotating Machinery (10,000 kVA and Larger) |
| IEEE 510-1983 | IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing |
| IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
| IEEE 95-2002 | IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage |