IEEE C57.12.91-2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
04-29-2021
English
02-13-2012
1. Overview
2. Normative references
3. Definitions
4. General
5. Resistance measurements
6. Polarity and phase-relation tests
7. Ratio tests
8. No-load losses and excitation current
9. Load losses and impedance voltage
10. Dielectric tests
11. Temperature test
12. Short-circuit tests
13. Audible sound-level measurements
14. Mechanical design tests
15. Calculated data
16. Minimum information to be included in certified
test data
Annex A (informative) - Bibliography
Defines methods for performing tests specified in IEEE Std C57.12.01[TM] and other referenced standards applicable to dry-type distribution and power transformers.
Committee |
Transformers
|
DevelopmentNote |
Supersedes IEEE DRAFT C57.12.91. (04/2001)
|
DocumentType |
Standard
|
ISBN |
978-0-7381-7193-7
|
Pages |
94
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
IEEE C57.94-1982 | IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power Transformers |
IEEE DRAFT C57.123 : D1.7 OCT 2000 | DRAFT GUIDE FOR TRANSFORMER LOSS MEASUREMENT |
IEEE 1653.2-2009 | IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications Up to 1500 V DC Nominal Output |
CSA C802.2 : 2012 | MINIMUM EFFICIENCY VALUES FOR DRY-TYPE TRANSFORMERS |
IEEE C57.32-2015 | IEEE Standard for Requirements, Terminology, and Test Procedures for Neutral Grounding Devices |
IEEE C57.123-2010 REDLINE | IEEE Guide for Transformer Loss Measurement |
CSA C802.2 : 2012 : INC : UPD 1 : 2013 | MINIMUM EFFICIENCY VALUES FOR DRY-TYPE TRANSFORMERS |
IEEE C57.12.51-2008 | IEEE Standard for Ventilated Dry- Type Power Transformers, 501 kVA and Larger, Three-Phase, with High- Voltage 601 V to 34 500 V; Low- Voltage 208Y/120 V to 4160 V- General Requirements |
IEEE DRAFT 1147 : D8 2005 | GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS |
IEEE C57.12.20-2011 REDLINE | IEEE Standard for Overhead-Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and Below |
IEEE 421.4-2014 | IEEE Guide for the Preparation of Excitation System Specifications |
IEEE C57.110-2008 REDLINE | IEEE Recommended Practice for Establishing Liquid-Filled and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load Currents |
IEEE DRAFT C57.12.60 : OCT 97 | DRAFT GUIDE FOR TEST PROCEDURES FOR THERMAL EVALUATION OF INSULATION SYSTEMS FOR SOLID-CAST AND RESIN-ENCAPSULATED POWER AND DISTRIBUTION TRANSFORMERS |
IEEE DRAFT C57.110 : D7 FEB 98 | DRAFT RECOMMENDED PRACTICE FOR ESTABLISHING TRANSFORMER CAPABILITY WHEN SUPPLYING NONSINUSOIDAL LOAD CURRENTS |
CSA C802.5 : 2016 | GUIDELINE FOR EVALUATING THE EFFICIENCY OF DRY-TYPE TRANSFORMERS UNDER NON-LINEAR LOADING |
IEEE C57.98-2011 | IEEE Guide for Transformer Impulse Tests |
ANSI C57.12.52 : 2012 | Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements |
IEEE C37.302-2015 | IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC |
IEEE DRAFT 389 : 1995 | RECOMMENDED PRACTICE FOR TESTING ELECTRONICS TRANSFORMERS AND INDUCTORS |
NEMA ST 20:2014 | Dry Type Transformers for General Applications |
NEMA TP 2-2005 | STANDARD TEST METHOD FOR MEASURING THE ENERGY CONSUMPTION OF DISTRIBUTION TRANSFORMERS |
NEMA TR1 : 2013 | TRANSFORMERS, STEP VOLTAGE REGULATORS AND REACTORS |
IEEE C57.12.01-2015 REDLINE | IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers |
UFC 3-550-01 : CHANGE 1 | UNIFIED FACILITIES CRITERIA - EXTERIOR ELECTRICAL POWER DISTRIBUTION |
IEEE 389-1996 | IEEE Recommended Practice for Testing Electronics Transformers and Inductors |
IEEE DRAFT C37.91 : D7.0 2006 | PROTECTING POWER TRANSFORMERS |
IEEE 421.3-1997 | IEEE Standard for High-Potential Test Requirements for Excitation Systems for Synchronous Machines |
IEEE 638-2013 | IEEE Standard for Qualification of Class 1E Transformers for Nuclear Power Generating Stations |
IEEE DRAFT C57.18.10 : D12 APR 97 | DRAFT PRACTICES AND REQUIREMENTS FOR SEMICONDUCTOR POWER RECTIFIER TRANSFORMER |
CSA C802.2 : 2012 : R2017 | MINIMUM EFFICIENCY VALUES FOR DRY-TYPE TRANSFORMERS |
IEEE C57.12.60-2009 REDLINE | IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers |
CSA C22.2 No. 66.1 : 2006 : INC : UPD 2 : 2013 : R201100 | LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 66.1 : 2006 : INC : UPD 1 : 2012 : R201100 | LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 66.1 : 2006 : R2011 | LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 66.1 : 2006 | LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 66.1 : 2006 : R2015 | LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
IEEE C57.134-2013 | IEEE Guide for Determination of Hottest-Spot Temperature in Dry-Type Transformers |
IEEE 1100 : 2005 | POWERING AND GROUNDING ELECTRONIC EQUIPMENT |
FAA AC 150/5345-47 : 2005 | SPECIFICATION FOR SERIES TO SERIES ISOLATION TRANSFORMERS FOR AIRPORT LIGHTING SYSTEMS |
IEEE C57.12.58-1991 | IEEE Guide for Conducting a Transient Voltage Analysis of a Dry-Type Transformer Coil |
IEEE DRAFT C57.12.01 : D6 2005 | GENERAL REQUIREMENTS FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS INCLUDING THOSE WITH SOLID-CAST AND/OR RESIN ENCAPSULATED WINDINGS |
ANSI C57.12.57 : 1987 | AMERICAN NATIONAL STANDARD FOR TRANSFORMERS - VENTILATED DRY-TYPE NETWORK TRANSFORMERS 2500 KVA AND BELOW, THREE-PHASE, WITH HIGH-VOLTAGE 34500 VOLTS AND BELOW, LOW-VOLTAGE 216Y/125 AND 480Y/227 VOLTS - REQUIREMENTS |
IEEE C57.159-2016 | IEEE Guide on Transformers for Application in Distributed Photovoltaic (DPV) Power Generation Systems |
IEEE C57.12.50 : 1981 | REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS |
IEEE C57.12.52-2012 | IEEE Standard for Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements |
CSA C22.2 No. 66 : 0 | SPECIALITY TRANSFORMERS |
IEEE 1147-2005 | IEEE Guide for the Rehabilitation of Hydroelectric Power Plants |
IEEE C57.12.11-1980 | IEEE Guide for Installation of Oil-Immersed Transformers (10 MVA and Larger, 69-287 kV Rating) |
IEEE 1653.1-2016 | IEEE Standard for Traction Power Rectifier Transformers for Substation Applications up to 1500 V DC Nominal Output |
C9-17 | Dry-type transformers |
CSA C22.2 No. 47 : 2013 | AIR-COOLED TRANSFORMERS (DRY TYPE) |
ASHRAE 90.4 : 2016 | ENERGY STANDARD FOR DATA CENTERS |
IEEE C57.94-2015 | IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type Distribution and Power Transformers |
IEEE C57.123-2019 | IEEE Guide for Transformer Loss Measurement |
IEEE C57.12.20-2017 | IEEE Standard for Overhead-Type Distribution Transformers 500 kVA and Smaller; High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and Below |
IEEE C57.12.60-2020 REDLINE | IEEE Standard for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers |
IEEE C57.12.58-2017 | IEEE Guide for Conducting a Transient Voltage Analysis of a Dry-Type Transformer Coil |
IEEE 421.3-2016 REDLINE | IEEE Standard for High-Potential Test Requirements for Excitation Systems for Synchronous Machines |
IEEE 1653.2-2020 REDLINE | IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications up to 1500 V DC Nominal Output |
IEEE C57.12.51-2019 | IEEE Guide for Mechanical Interchangeability of Ventilated Dry-Type Transformers |
IEEE C57.12.51-2008 | REQUIREMENTS FOR SEALED DRY-TYPE POWER TRANSFORMERS, 501 KVA AND LARGER, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 208Y/120 TO 4160 VOLTS |
IEEE 99-2007 REDLINE | IEEE Recommended Practice for the Preparation of Test Procedures for the Thermal Evaluation of Insulation Systems for Electrical Equipment |
IEEE C57.12.59-2015 | IEEE Guide for Dry-Type Transformer Through-Fault Current Duration |
IEEE C57.12.01-2015 REDLINE | IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers |
IEEE C57.134-2013 | IEEE Guide for Determination of Hottest-Spot Temperature in Dry-Type Transformers |
IEEE 4-1995 | IEEE Standard Techniques for High-Voltage Testing |
ANSI S1.4 : 1983 | SPECIFICATION FOR SOUND LEVEL METERS |
ANSI S1.11 : 2014 | SPECIFICATION FOR OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND ANALOG AND DIGITAL FILTERS |
IEEE C57.12.60-2009 REDLINE | IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers |
IEEE C57.12.58-1991 | IEEE Guide for Conducting a Transient Voltage Analysis of a Dry-Type Transformer Coil |
IEEE C57.96-2013 | IEEE Guide for Loading Dry-Type Distribution and Power Transformers |
IEEE C57.12.01-2005 | IEEE Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated Windings |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE C57.124 : 1991 | RECOMMENDED PRACTICE FOR THE DETECTION OF PARTIAL DISCHARGE AND THE MEASUREMENT OF APPARENT CHARGE IN DRY-TYPE TRANSFORMERS |
ANSI C57.12.52 : 2012 | Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements |
IEEE C57.98-2011 | IEEE Guide for Transformer Impulse Tests |
IEEE C57.12.70-2011 | IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers |
IEEE C57.98-1993 | IEEE Guide for Transformer Impulse Tests |
IEEE C57.12.50 : 1981 | REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS |
ANSI C57.12.57 : 1987 | AMERICAN NATIONAL STANDARD FOR TRANSFORMERS - VENTILATED DRY-TYPE NETWORK TRANSFORMERS 2500 KVA AND BELOW, THREE-PHASE, WITH HIGH-VOLTAGE 34500 VOLTS AND BELOW, LOW-VOLTAGE 216Y/125 AND 480Y/227 VOLTS - REQUIREMENTS |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.