IEEE DRAFT 404 : D13 2006
Withdrawn
View Superseded by
EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V
01-12-2013
10-17-2023
1 Scope
2 Normative References
3 Definitions
3.1 Cable joint categories
3.2 Joint constructions
3.3 Other terms
4 Service conditions
5 Ratings
5.1 Voltage
5.2 Current and Temperature
6 Construction
6.1 Identification
6.2 Shielding
6.3 Sheath/shield sectional
7 Testing
7.1 Production tests for premolded and single-component
cold-shrink joints
7.2 Fingerprint tests for heat-shrink and multi-component
cold-shrink joint components
7.3 Fingerprint tests for elastomeric taped-joint components
7.4 Design tests and testing sequence for all joint types
7.5 Design test conditions
7.6 Dielectric integrity tests
7.7 Voltage Withstand tests
7.8 Short-time current test
7.9 Cyclic aging test for extruded dielectric and transition
joints
7.10 High-voltage time test
7.11 Sectionalizer tests
7.12 Semiconducting shielding test
7.13 Cable metallic-shield restoration and cable jacket
restoration components
7.14 Connector thermal and mechanical tests
Annexes
Annex A: (Informative) Typical values of heat-shrinkable and
multi-component cold-shrink joint component tests
and sampling rates
Annex B: (Informative) Typical values of elastomeric taped-joint
component tests and sampling rates
Annex C: (Informative) Bibliography
Lays down electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cables rated in preferred voltage steps from 2500 V to 500 000 V. In addition, it defines test requirements for cable jacket and cable shield restoration devices.
| DocumentType |
Draft
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| SupersededBy |
| ASTM D 4325 : 2013 : REDLINE | Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes |
| ASTM D 4496 : 2013 | Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials |
| ASTM D 4388 : 2013 | Standard Specification for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes |
| IEC 60502-4:2010 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
| IEEE 592-2007 REDLINE | IEEE Standard for Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable Connectors |
| WC 5-1992 | THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
| IEEE 82 : 2002 | TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS |
| WC 8:1988 | ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
| ICEA P 32 382 : 2007(R2018) | SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES |
| WC 4-1988/ICEA S-65-375 3rd Ed. (R1993) | VARNISHED-CLOTH-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
| IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
| ICEA S 94 649 : 2013 | CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV |
| IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
| WC 3-1992 | RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
| ICEA S 97 682 : 2013 | UTILITY SHIELDED POWER CABLES RATED 5 THROUGH 46 KV |
| IEEE 575-2014 | IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kV |
| WC 7-1988 | CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |