IEEE DRAFT 404 : D13 2006

Withdrawn

Withdrawn

View Superseded by

EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V

Published date

01-12-2013

Withdrawn date

10-17-2023

Superseded by

IEEE 404-2012

Sorry this product is not available in your region.

1 Scope
2 Normative References
3 Definitions
  3.1 Cable joint categories
  3.2 Joint constructions
  3.3 Other terms
4 Service conditions
5 Ratings
  5.1 Voltage
  5.2 Current and Temperature
6 Construction
  6.1 Identification
  6.2 Shielding
  6.3 Sheath/shield sectional
7 Testing
  7.1 Production tests for premolded and single-component
       cold-shrink joints
  7.2 Fingerprint tests for heat-shrink and multi-component
       cold-shrink joint components
  7.3 Fingerprint tests for elastomeric taped-joint components
  7.4 Design tests and testing sequence for all joint types
  7.5 Design test conditions
  7.6 Dielectric integrity tests
  7.7 Voltage Withstand tests
  7.8 Short-time current test
  7.9 Cyclic aging test for extruded dielectric and transition
       joints
  7.10 High-voltage time test
  7.11 Sectionalizer tests
  7.12 Semiconducting shielding test
  7.13 Cable metallic-shield restoration and cable jacket
       restoration components
  7.14 Connector thermal and mechanical tests
Annexes
Annex A: (Informative) Typical values of heat-shrinkable and
         multi-component cold-shrink joint component tests
         and sampling rates
Annex B: (Informative) Typical values of elastomeric taped-joint
         component tests and sampling rates
Annex C: (Informative) Bibliography

Lays down electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cables rated in preferred voltage steps from 2500 V to 500 000 V. In addition, it defines test requirements for cable jacket and cable shield restoration devices.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
SupersededBy

ASTM D 4325 : 2013 : REDLINE Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes
ASTM D 4496 : 2013 Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials
ASTM D 4388 : 2013 Standard Specification for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes
IEC 60502-4:2010 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
IEEE 592-2007 REDLINE IEEE Standard for Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable Connectors
WC 5-1992 THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEEE 82 : 2002 TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS
WC 8:1988 ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
ICEA P 32 382 : 2007(R2018) SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES
WC 4-1988/ICEA S-65-375 3rd Ed. (R1993) VARNISHED-CLOTH-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
ICEA S 94 649 : 2013 CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
WC 3-1992 RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
ICEA S 97 682 : 2013 UTILITY SHIELDED POWER CABLES RATED 5 THROUGH 46 KV
IEEE 575-2014 IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kV
WC 7-1988 CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY

Sorry this product is not available in your region.