IEEE 575-2014
Withdrawn
IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kV
Hardcopy , PDF
English
09-18-2014
03-27-2025
1 Overview
2 Normative references
3 Definitions
4 Background
5 Shield optimization
6 Special bonding techniques
7 Sheath voltage limiters
8 Effect on parallel communication and control
cables
Annex A (informative) - Bibliography
Annex B (informative) - Discussion of early
practices and problems
Annex C (informative) - Current practice for
shield/sheath standing voltages
Annex D (informative) - Calculation of induced
voltages
Annex E (informative) - Transient voltages and
voltage withstand requirements of
protective jackets
Annex F (informative) - Current and voltage
distribution on cable shields/sheaths with
multiple cables per phase
The most common shield/sheath-bonding systems now in use on medium through extra high-voltage (5 kV to 500 kV) single-conductor shielded power cables and the methods of calculating the corresponding shield/sheath voltages and currents, when the cables are operated as part of a three-phase system, with the neutral grounded directly or through an impedance, are described in this guide.
| Committee |
Insulated Conductors
|
| DocumentType |
Standard
|
| ISBN |
978-0-7381-9228-4
|
| Pages |
83
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| Supersedes |
| IEEE DRAFT C62.22 : D8 2005 | GUIDE FOR THE APPLICATION OF METAL-OXIDE SURGE ARRESTERS FOR ALTERNATING-CURRENT SYSTEMS |
| IEEE 1242-1999 | IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants |
| IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
| IEEE DRAFT 525 : D15 2006 | DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS |
| IEEE DRAFT 404 : D13 2006 | EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V |
| IEEE 1816-2013 | IEEE Guide for Preparation Techniques of Extruded Dielectric, Shielded Cables Rated 2.5 kV through 46 kV and the Installation of Mating Accessories |
| IEEE 3001.5-2013 | IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems |
| IEEE 45.8-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Cable Systems |
| IEEE 532-2007 REDLINE | IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables |
| IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
| IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
| IEEE 404-2012 | IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV |
| IEEE 525-2016 REDLINE | IEEE Guide for the Design and Installation of Cable Systems in Substations |
| IEEE 404-2022 | IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV |
| IEC 60287-1-3:2002 | Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses |
| ICEA P 32 382 : 2007(R2018) | SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES |
| IEEE C2-2017 | NATIONAL ELECTRICAL SAFETY CODE (NESC)(R) |