ISA 60079-6 : 1998
Withdrawn
View Superseded by
EXPLOSIVE ATMOSPHERES - PART 6: EQUIPMENT PROTECTION BY OIL-IMMERSION 'O'
English
01-01-1998
01-01-2016
General Notes
Preface (ISA)
National Differences
Foreword (ISA)
1 Scope
2 References
3 Terms and definitions
4 Constructional requirements
5 Verifications and tests
6 Marking
7 Instructions
Annex A (informative) - Introduction of an alternative risk
assessment method encompassing 'equipment protection
levels' for Ex equipment
Annex B (informative) - United States major deviations
Describes the requirements for the construction and testing of oilimmersed electrical equipment, oil-immersed parts of electrical equipment and Ex components in the type of protection oil immersion 'o', intended for use in explosive gas atmospheres.
| DevelopmentNote |
Supersedes and Renumbers ISA 12.26.01 (09/2005) Also numbered as UL 60079-6. (08/2009)
|
| DocumentType |
Standard
|
| Pages |
32
|
| PublisherName |
International Society of Automation
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
| FM 3600 : 2018 | ELECTRICAL EQUIPMENT FOR USE IN HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
| CSA C22.4 No. 1 : 2009(R2018) | OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE |
| FM 3640 : 2013 | LAND MOBILE RADIOS FOR USE IN CLASS I, DIVISION 1 HAZARDOUS (CLASSIFIED) LOCATIONS |
| NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
| API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
| API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| ISA 60079-7 : 2008 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E" |
| IEC 60156:1995 | Insulating liquids - Determination of the breakdown voltage at power frequency - Test method |
| ISA 60079-11 : 2002 | EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I' |
| ISA 60079-0 : 2005 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
| ISA 60079-15 : 2003 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |