NEMA SG 3 : 1995
Withdrawn
LOW-VOLTAGE POWER CIRCUIT BREAKERS
01-12-2013
04-12-2000
1 Referenced standards
Referenced standards
2 Metal-enclosed low-voltage power circuit breaker
switchgear
Exceptions to American National Standard
C37.20.1-1987
3 Metal-clad and station-type cubicle switchgear
Exceptions to American National Standard
C37.20.2-1987
4 Metal-enclosed interrupter switchgear
Exceptions to American National Standard
C37.20.3-1987
5 Control switchboards
Exceptions to American National Standard
C37.21-1988
6 Metal-enclosed bus and calculating losses in
isolated-phase bus
Exceptions to American National Standard
C37.23-1987
7 Guide for evaluating the effects of solar radiation
on outdoor metal-enclosed switchgear
Exceptions to American National Standard
C37.24-1988
8 Conformance testing of metal-enclosed low-voltage AC
power circuit breaker switchgear assemblies
Exceptions to American National Standard
C37.51-1988
9 Definitions for power switchgear
Exceptions to American National Standard
C37.100-1981
Covers assembling equipment for control and protection of apparatus used for power generation, conversion, transmission, and distribution; metal enclosed power bus and connections; control switchboards; renewal and spare parts designed for switchgear assemblies. Includes the following sections: metal enclosed low voltage power circuit breaker switchgear; metal clad and station type cubicle switchgear; metal enclosed bus and calculating losses in isolated phase bus; definitions for power switchgear; guide for evaluating the effects of solar radiation on outdoor metal enclosed switchgear.
| DocumentType |
Standard
|
| PublisherName |
National Electrical Manufacturers Association
|
| Status |
Withdrawn
|
| ANS 57.7-1988(R1997) | DESIGN CRITERIA FOR AN INDEPENDENT SPENT FUEL STORAGE INSTALLATION (WATER POOL TYPE) |
| IEEE 902-1998 | IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book) (Color Book® Series) |
| IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
| IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) (Color Book® Series) |
| MIL-C-11085 Revision D:1986 | Conveyor, Belt; (Flat, Skid-Mounted, Electric-Motor-Driven, 24-Inch-Wide Belt, 50-Foot-Long Frame; Capacity, 25 Pounds Per Foot, 75 Tons Per Hour) (No S/S Document) |
| IEEE C37.20.1-2015 | IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear |
| ANSI C37.51 : 1989 | SWITCHGEAR - METAL-ENCLOSED LOW-VOLTAGE AC POWER - CIRCUIT BREAKER SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
| IEEE C37.20.2-2015 | IEEE Standard for Metal-Clad Switchgear |
| IEEE C37.20.3-2013 REDLINE | IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV) |
| IEEE C37.24-2003 | IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear |
| IEEE C37.21-2005 | IEEE Standard for Control Switchboards |
| IEEE C37.23-2003 | IEEE Standard for Metal-Enclosed Bus |