NF EN 61377-3 : 2003
Current
RAILWAY APPLICATIONS - ROLLING STOCK - PART 3: COMBINED TESTING OF ALTERNATING CURRENT MOTORS, FED BY AN INDIRECT CONVERTOR, AND THEIR CONTROL SYSTEM
01-12-2013
1 Scope and object
2 Normative references
3 Definitions
4 Environmental conditions
5 Combined system characteristics
5.1 Specified characteristics
5.2 Declared characteristics
5.3 Combined system characteristics
5.4 Exchange of information and responsibility
6 Test categories
6.1 General
6.2 Type tests
6.3 Investigation tests
7 Tests
7.1 General
7.2 Test conditions
7.3 Temperature-rise tests
7.4 Additional test for paralleled asynchronous motors
7.5 Characteristic tests and tolerances
7.6 Miscellaneous tests
7.7 Investigation tests
Annex A (normative) Agreement between user and manufacturer
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Specifies: a) the performance characteristics of electric drives consisting of a convertor, alternating current motors, and the related control system; b) methods of verifying these performance characteristics by tests.
| DevelopmentNote |
Indice de Classement: F65-377-3 PR NF EN 61377-3 Juillet 2001 (07/2001)
|
| DocumentType |
Standard
|
| PublisherName |
Association Francaise de Normalisation
|
| Status |
Current
|
| Standards | Relationship |
| EN 61377-3:2002 | Identical |
| DIN EN 61377-3 : 2003 | Identical |
| IEC 61377-3:2002 | Identical |
| BS EN 61377-3:2002 | Identical |
| NBN EN 61377-3 : 2003 | Identical |
| I.S. EN 61377-3:2003 | Identical |
| UNE-EN 61377-3:2004 | Identical |