S.R. CEN TR 15983:2010
Withdrawn
STATIONARY SOURCE EMISSIONS - GUIDANCE ON THE APPLICATION OF EN 14181:2004
Hardcopy , PDF
English
01-01-2010
03-22-2016
Foreword
Introduction
1 Scope
2 Terms and definitions
3 Symbols and abbreviations
4 General guidance on quality assurance and calibration
5 Application of QAL1
6 Application of QAL2 and AST
7 Calibration and validation of the AMS
8 On-going surveillance and quality assurance of AMS (QAL3)
Annex A (informative) An example of a procedure for
determining outliers
Annex B (informative) Alternative approaches for dealing
with low-level clusters of emissions
Annex C (informative) k[v] values
Annex D (informative) Shewhart and EWMA control charts
Bibliography
Gives guidance only on applying the quality assurance levels QAL1, QAL2 and QAL3 as well as the Annual Surveillance Test (AST).
| DocumentType |
Standard
|
| Pages |
46
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Withdrawn
|
| Standards | Relationship |
| CEN/TR 15983:2010 | Identical |
| CEN/TR 15983:2010 | Equivalent |
| PD CEN/TR 15983:2010 | Equivalent |
| CEN/TS 15675:2007 | Air quality - Measurement of stationary source emissions - Application of EN ISO/IEC 17025:2005 to periodic measurements |
| ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
| EN 15267-3:2007 | Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources |
| ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
| EN ISO 9169:2006 | Air quality - Definition and determination of performance characteristics of an automatic measuring system (ISO 9169:2006) |
| ISO 11095:1996 | Linear calibration using reference materials |
| EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
| EN 13284-2:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems |
| EN 14181:2014 | Stationary source emissions - Quality assurance of automated measuring systems |
| EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
| EN 12619:2013 | Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method |
| EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
| ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
| ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
| EN ISO 14001:2015 | Environmental management systems - Requirements with guidance for use (ISO 14001:2015) |
| ISO 9001:2015 | Quality management systems — Requirements |
| EN ISO 10012:2003 | Measurement management systems - Requirements for measurement processes and measuring equipment (ISO 10012:2003) |
| EN 14792:2017 | Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence |
| EN 15267-1:2009 | Air quality - Certification of automated measuring systems - Part 1: General principles |
| ISO 9169:2006 | Air quality — Definition and determination of performance characteristics of an automatic measuring system |